{"_buckets": {"deposit": "b6062b0f-6f09-4108-b373-89d7a9b908ff"}, "_deposit": {"created_by": 1, "id": "13791", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "13791"}, "status": "published"}, "_oai": {"id": "oai:jaxa.repo.nii.ac.jp:00013791", "sets": ["1646", "1891"]}, "author_link": ["126613", "126608", "126610", "126614", "126617", "126605", "126606", "126616", "126604", "126611", "126615", "126607", "126612", "126609"], "item_5_alternative_title_2": {"attribute_name": "その他のタイトル(英)", "attribute_value_mlt": [{"subitem_alternative_title": "Space dosimetry with a tissue equivalent position sensitive proportional counter"}]}, "item_5_biblio_info_10": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2005-03", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "269", "bibliographicPageStart": "266", "bibliographic_titles": [{"bibliographic_title": "宇宙利用シンポジウム 第21回 平成16年度"}, {"bibliographic_title": "Space Utilization Research: Proceedings of the Twenty-first Space Utilization Symposium", "bibliographic_titleLang": "en"}]}]}, "item_5_description_17": {"attribute_name": "抄録(英)", "attribute_value_mlt": [{"subitem_description": "It is essential to evaluate the radiation risk for astronaut in space. The development of a new space dosimeter named \u0027Position Sensitive Tissue Equivalent Proportional Counter\u0027 (PS-TEPC) is started. This detector has good properties of both exiting dosimeters such as TEPC in NASA and Real-time Radiation Monitoring Device-3 (RRMD-3) based on a Si telescope. A novel technique named Micro PIxel Chamber (Micro-PIC) makes it feasible.", "subitem_description_type": "Other"}]}, "item_5_description_32": {"attribute_name": "資料番号", "attribute_value_mlt": [{"subitem_description": "資料番号: AA0048095062", "subitem_description_type": "Other"}]}, "item_5_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "宇宙航空研究開発機構宇宙科学研究本部"}]}, "item_5_publisher_9": {"attribute_name": "出版者(英)", "attribute_value_mlt": [{"subitem_publisher": "Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency (JAXA/ISAS)"}]}, "item_5_text_20": {"attribute_name": "その他キーワード", "attribute_value_mlt": [{"subitem_text_value": "計装(計測制御装置の装備技術)及び写真技術"}, {"subitem_text_value": "宇宙船計装"}]}, "item_5_text_35": {"attribute_name": "JAXAカテゴリ", "attribute_value_mlt": [{"subitem_text_value": "JAXAカテゴリ: シンポジウム・研究会"}]}, "item_5_text_36": {"attribute_name": "JAXAカテゴリ2", "attribute_value_mlt": [{"subitem_text_value": "JAXAカテゴリ2: IS"}]}, "item_5_text_42": {"attribute_name": "シンポジウム区分", "attribute_value_mlt": [{"subitem_text_value": "シンポジウム区分: 008"}]}, "item_5_text_43": {"attribute_name": "DSpaceコレクション番号", "attribute_value_mlt": [{"subitem_text_value": "DSpaceコレクション番号: 7"}]}, "item_5_text_6": {"attribute_name": "著者所属", "attribute_value_mlt": [{"subitem_text_value": "早稲田大学 理工学総合研究センター"}, {"subitem_text_value": "早稲田大学 理工学総合研究センター"}, {"subitem_text_value": "宇宙航空研究開発機構 総合技術研究本部"}, {"subitem_text_value": "京都大学 大学院理学研究科"}, {"subitem_text_value": "京都大学 大学院理学研究科"}, {"subitem_text_value": "高エネルギー加速器研究機構 放射線科学センター"}, {"subitem_text_value": "高エネルギー加速器研究機構 放射線科学センター"}]}, "item_5_text_7": {"attribute_name": "著者所属(英)", "attribute_value_mlt": [{"subitem_text_language": "en", "subitem_text_value": "Waseda University Advanced Research Institute for Science and Engineering"}, {"subitem_text_language": "en", "subitem_text_value": "Waseda University Advanced Research Institute for Science and Engineering"}, {"subitem_text_language": "en", "subitem_text_value": "Japan Aerospace Exploration Agency Institute of Space Technology and Aeronautics"}, {"subitem_text_language": "en", "subitem_text_value": "Kyoto University Graduate School of Science"}, {"subitem_text_language": "en", "subitem_text_value": "Kyoto University Graduate School of Science"}, {"subitem_text_language": "en", "subitem_text_value": "High Energy Accelerator Research Organization Radiation Science Center"}, {"subitem_text_language": "en", "subitem_text_value": "High Energy Accelerator Research Organization Radiation Science Center"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "寺沢, 和洋"}], "nameIdentifiers": [{"nameIdentifier": "126604", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "道家, 忠義"}], "nameIdentifiers": [{"nameIdentifier": "126605", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松本, 晴久"}], "nameIdentifiers": [{"nameIdentifier": "126606", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "身内, 賢太朗"}], "nameIdentifiers": [{"nameIdentifier": "126607", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "永吉, 勉"}], "nameIdentifiers": [{"nameIdentifier": "126608", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐々木, 慎一"}], "nameIdentifiers": [{"nameIdentifier": "126609", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "俵, 裕子"}], "nameIdentifiers": [{"nameIdentifier": "126610", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Terasawa, Kazuhiro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "126611", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Doke, Tadayoshi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "126612", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsumoto, Haruhisa", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "126613", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Miuchi, Kentaro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "126614", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nagayoshi, Tsutomu", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "126615", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sasaki, Shinichi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "126616", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tawara, Hiroko", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "126617", "nameIdentifierScheme": "WEKO"}]}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "線量計", "subitem_subject_scheme": "Other"}, {"subitem_subject": "線形エネルギー輸送", "subitem_subject_scheme": "Other"}, {"subitem_subject": "線量等量", "subitem_subject_scheme": "Other"}, {"subitem_subject": "宇宙線", "subitem_subject_scheme": "Other"}, {"subitem_subject": "比例計数管", "subitem_subject_scheme": "Other"}, {"subitem_subject": "中性子", "subitem_subject_scheme": "Other"}, {"subitem_subject": "被曝線量", "subitem_subject_scheme": "Other"}, {"subitem_subject": "マイクロピクセル電離箱", "subitem_subject_scheme": "Other"}, {"subitem_subject": "位置有感検出器", "subitem_subject_scheme": "Other"}, {"subitem_subject": "組織等価比例計数管", "subitem_subject_scheme": "Other"}, {"subitem_subject": "dosimeter", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Linear Energy Transfer", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "dose equivalent", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "cosmic ray", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "proportional counter", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "neutron", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "radiation dosage", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "micro pixel chamber", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "position sensitive detector", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "tissue equivalent proportional counter", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "生体組織等価位置有感比例計数管による宇宙放射線線量当量計測器の開発", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "生体組織等価位置有感比例計数管による宇宙放射線線量当量計測器の開発"}]}, "item_type_id": "5", "owner": "1", "path": ["1646", "1891"], "permalink_uri": "https://jaxa.repo.nii.ac.jp/records/13791", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-03-26"}, "publish_date": "2015-03-26", "publish_status": "0", "recid": "13791", "relation": {}, "relation_version_is_last": true, "title": ["生体組織等価位置有感比例計数管による宇宙放射線線量当量計測器の開発"], "weko_shared_id": -1}
生体組織等価位置有感比例計数管による宇宙放射線線量当量計測器の開発
https://jaxa.repo.nii.ac.jp/records/13791
https://jaxa.repo.nii.ac.jp/records/13791c5d88faf-c9ba-4c48-a69c-32887b510eea
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-03-26 | |||||
タイトル | ||||||
タイトル | 生体組織等価位置有感比例計数管による宇宙放射線線量当量計測器の開発 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 線量計 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 線形エネルギー輸送 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 線量等量 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 宇宙線 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 比例計数管 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 中性子 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 被曝線量 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | マイクロピクセル電離箱 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 位置有感検出器 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 組織等価比例計数管 | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | dosimeter | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Linear Energy Transfer | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | dose equivalent | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | cosmic ray | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | proportional counter | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | neutron | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | radiation dosage | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | micro pixel chamber | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | position sensitive detector | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | tissue equivalent proportional counter | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
その他のタイトル(英) | ||||||
その他のタイトル | Space dosimetry with a tissue equivalent position sensitive proportional counter | |||||
著者 |
寺沢, 和洋
× 寺沢, 和洋× 道家, 忠義× 松本, 晴久× 身内, 賢太朗× 永吉, 勉× 佐々木, 慎一× 俵, 裕子× Terasawa, Kazuhiro× Doke, Tadayoshi× Matsumoto, Haruhisa× Miuchi, Kentaro× Nagayoshi, Tsutomu× Sasaki, Shinichi× Tawara, Hiroko |
|||||
著者所属 | ||||||
早稲田大学 理工学総合研究センター | ||||||
著者所属 | ||||||
早稲田大学 理工学総合研究センター | ||||||
著者所属 | ||||||
宇宙航空研究開発機構 総合技術研究本部 | ||||||
著者所属 | ||||||
京都大学 大学院理学研究科 | ||||||
著者所属 | ||||||
京都大学 大学院理学研究科 | ||||||
著者所属 | ||||||
高エネルギー加速器研究機構 放射線科学センター | ||||||
著者所属 | ||||||
高エネルギー加速器研究機構 放射線科学センター | ||||||
著者所属(英) | ||||||
en | ||||||
Waseda University Advanced Research Institute for Science and Engineering | ||||||
著者所属(英) | ||||||
en | ||||||
Waseda University Advanced Research Institute for Science and Engineering | ||||||
著者所属(英) | ||||||
en | ||||||
Japan Aerospace Exploration Agency Institute of Space Technology and Aeronautics | ||||||
著者所属(英) | ||||||
en | ||||||
Kyoto University Graduate School of Science | ||||||
著者所属(英) | ||||||
en | ||||||
Kyoto University Graduate School of Science | ||||||
著者所属(英) | ||||||
en | ||||||
High Energy Accelerator Research Organization Radiation Science Center | ||||||
著者所属(英) | ||||||
en | ||||||
High Energy Accelerator Research Organization Radiation Science Center | ||||||
出版者 | ||||||
出版者 | 宇宙航空研究開発機構宇宙科学研究本部 | |||||
出版者(英) | ||||||
出版者 | Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency (JAXA/ISAS) | |||||
書誌情報 |
宇宙利用シンポジウム 第21回 平成16年度 en : Space Utilization Research: Proceedings of the Twenty-first Space Utilization Symposium p. 266-269, 発行日 2005-03 |
|||||
抄録(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | It is essential to evaluate the radiation risk for astronaut in space. The development of a new space dosimeter named 'Position Sensitive Tissue Equivalent Proportional Counter' (PS-TEPC) is started. This detector has good properties of both exiting dosimeters such as TEPC in NASA and Real-time Radiation Monitoring Device-3 (RRMD-3) based on a Si telescope. A novel technique named Micro PIxel Chamber (Micro-PIC) makes it feasible. | |||||
資料番号 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 資料番号: AA0048095062 |