WEKO3
アイテム
{"_buckets": {"deposit": "8c8a6aa1-97d3-4601-99d5-41a83726bb97"}, "_deposit": {"created_by": 1, "id": "22478", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "22478"}, "status": "published"}, "_oai": {"id": "oai:jaxa.repo.nii.ac.jp:00022478", "sets": ["1888"]}, "author_link": ["210824", "210825"], "item_7_biblio_info_10": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2014-04", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "4", "bibliographicPageEnd": "949", "bibliographicPageStart": "937", "bibliographicVolumeNumber": "161", "bibliographic_titles": [{}, {"bibliographic_title": "Combustion and Flame", "bibliographic_titleLang": "en"}]}]}, "item_7_description_17": {"attribute_name": "抄録(英)", "attribute_value_mlt": [{"subitem_description": "This article investigates the correlation between optical emission and turbulent length scale in a coaxial jet diffusion flame. To simulate the H2O emission from an H2/O2 diffusion flame, radiative transfer is calculated on flame data obtained by numerical simulation. H2O emission characteristics are examined for a one-dimensional opposed-flow diffusion flame. The results indicate that H2O emission intensity is linearly dependent on flame thickness. The simulation of H2O emission is then extended to an H2/O2 turbulent coaxial jet diffusion flame. Time series data for a turbulent diffusion flame are obtained by Large Eddy Simulation, and radiative transfer calculations are conducted on the LES results to simulate H2O emission optical images. The length scales of visible structures in the simulated emission images are determined by the procedure proposed by Ivancic and Mayer (2002) [8]. The length scales of emission intensity are compared with the integral length scales of velocity and temperature evaluated from LES flowfield data. The results clearly indicate that the length scale of emission intensity agrees well with the integral length scale of temperature, and is also close to that of the radial velocity component. Finally, the explanation as to why the integral length scale of temperature can be extracted from emission intensity distributions is stated.", "subitem_description_type": "Other"}]}, "item_7_description_32": {"attribute_name": "資料番号", "attribute_value_mlt": [{"subitem_description": "資料番号: PA1420027000", "subitem_description_type": "Other"}]}, "item_7_publisher_9": {"attribute_name": "出版者(英)", "attribute_value_mlt": [{"subitem_publisher": "Elsevier Combustion Institute"}]}, "item_7_relation_25": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "info:doi/10.1016/j.combustflame.2013.10.009"}], "subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://dx.doi.org/10.1016/j.combustflame.2013.10.009", "subitem_relation_type_select": "DOI"}}]}, "item_7_rights_28": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "(C) 2013 The Combustion Institute. Published by Elsevier Inc. || NOTICE: this is the author\u0027s version of a work that was accepted for publication in Combustion and flame. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in PUBLICATION, Volume 161, Issue 4, 2014, DOI:10.1016/j.combustflame.2013.10.009"}]}, "item_7_source_id_21": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0010-2180", "subitem_source_identifier_type": "ISSN"}]}, "item_7_source_id_22": {"attribute_name": "ISSNONLINE", "attribute_value_mlt": [{"subitem_source_identifier": "0010-2180", "subitem_source_identifier_type": "ISSN"}]}, "item_7_source_id_24": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA00610787", "subitem_source_identifier_type": "NCID"}, {"subitem_source_identifier": "AA11524905", "subitem_source_identifier_type": "NCID"}]}, "item_7_text_35": {"attribute_name": "JAXAカテゴリ", "attribute_value_mlt": [{"subitem_text_value": "JAXAカテゴリ: 学術雑誌論文"}]}, "item_7_text_36": {"attribute_name": "JAXAカテゴリ2", "attribute_value_mlt": [{"subitem_text_value": "JAXAカテゴリ2: AP"}]}, "item_7_text_43": {"attribute_name": "DSpaceコレクション番号", "attribute_value_mlt": [{"subitem_text_value": "DSpaceコレクション番号: 8"}]}, "item_7_text_6": {"attribute_name": "著者所属", "attribute_value_mlt": [{"subitem_text_value": "宇宙航空研究開発機構航空本部(JAXA)"}]}, "item_7_text_7": {"attribute_name": "著者所属(英)", "attribute_value_mlt": [{"subitem_text_language": "en", "subitem_text_value": "Institute of Aeronautical Technology, Japan Aerospace Exploration Agency (JAXA)"}]}, "item_7_version_type_30": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "松山, 新吾"}], "nameIdentifiers": [{"nameIdentifier": "210824", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsuyama, Shingo", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "210825", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-01-22"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "PA1420027.pdf", "filesize": [{"value": "4.7 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 4700000.0, "url": {"label": "PA1420027.pdf", "url": "https://jaxa.repo.nii.ac.jp/record/22478/files/PA1420027.pdf"}, "version_id": "17e12d4a-d916-40c4-ad6d-2bb4cb45d5fc"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "H2O emission", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Integral length scale", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Turbulent diffusion flame", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Large Eddy Simulation", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "OH* chemiluminescence", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Cryogenic rocket combustion", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Correlation of optical emission and turbulent length scale in a coaxial jet diffusion flame", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Correlation of optical emission and turbulent length scale in a coaxial jet diffusion flame", "subitem_title_language": "en"}]}, "item_type_id": "7", "owner": "1", "path": ["1888"], "permalink_uri": "https://jaxa.repo.nii.ac.jp/records/22478", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-03-26"}, "publish_date": "2015-03-26", "publish_status": "0", "recid": "22478", "relation": {}, "relation_version_is_last": true, "title": ["Correlation of optical emission and turbulent length scale in a coaxial jet diffusion flame"], "weko_shared_id": -1}
Correlation of optical emission and turbulent length scale in a coaxial jet diffusion flame
https://jaxa.repo.nii.ac.jp/records/22478
https://jaxa.repo.nii.ac.jp/records/2247874342cd2-425d-40bb-9458-21bcb0bd7c37
名前 / ファイル | ライセンス | アクション |
---|---|---|
PA1420027.pdf (4.7 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-03-26 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Correlation of optical emission and turbulent length scale in a coaxial jet diffusion flame | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | H2O emission | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Integral length scale | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Turbulent diffusion flame | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Large Eddy Simulation | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | OH* chemiluminescence | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Cryogenic rocket combustion | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
松山, 新吾
× 松山, 新吾× Matsuyama, Shingo |
|||||
著者所属 | ||||||
宇宙航空研究開発機構航空本部(JAXA) | ||||||
著者所属(英) | ||||||
en | ||||||
Institute of Aeronautical Technology, Japan Aerospace Exploration Agency (JAXA) | ||||||
出版者(英) | ||||||
出版者 | Elsevier Combustion Institute | |||||
書誌情報 |
en : Combustion and Flame 巻 161, 号 4, p. 937-949, 発行日 2014-04 |
|||||
抄録(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | This article investigates the correlation between optical emission and turbulent length scale in a coaxial jet diffusion flame. To simulate the H2O emission from an H2/O2 diffusion flame, radiative transfer is calculated on flame data obtained by numerical simulation. H2O emission characteristics are examined for a one-dimensional opposed-flow diffusion flame. The results indicate that H2O emission intensity is linearly dependent on flame thickness. The simulation of H2O emission is then extended to an H2/O2 turbulent coaxial jet diffusion flame. Time series data for a turbulent diffusion flame are obtained by Large Eddy Simulation, and radiative transfer calculations are conducted on the LES results to simulate H2O emission optical images. The length scales of visible structures in the simulated emission images are determined by the procedure proposed by Ivancic and Mayer (2002) [8]. The length scales of emission intensity are compared with the integral length scales of velocity and temperature evaluated from LES flowfield data. The results clearly indicate that the length scale of emission intensity agrees well with the integral length scale of temperature, and is also close to that of the radial velocity component. Finally, the explanation as to why the integral length scale of temperature can be extracted from emission intensity distributions is stated. | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0010-2180 | |||||
ISSNONLINE | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0010-2180 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA00610787 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA11524905 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | http://dx.doi.org/10.1016/j.combustflame.2013.10.009 | |||||
関連名称 | info:doi/10.1016/j.combustflame.2013.10.009 | |||||
権利 | ||||||
権利情報 | (C) 2013 The Combustion Institute. Published by Elsevier Inc. || NOTICE: this is the author's version of a work that was accepted for publication in Combustion and flame. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in PUBLICATION, Volume 161, Issue 4, 2014, DOI:10.1016/j.combustflame.2013.10.009 | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
資料番号 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 資料番号: PA1420027000 |