WEKO3
アイテム
{"_buckets": {"deposit": "44d66c70-4a2c-45ad-9bb4-c40c8154f9ce"}, "_deposit": {"created_by": 1, "id": "31502", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "31502"}, "status": "published"}, "_oai": {"id": "oai:jaxa.repo.nii.ac.jp:00031502", "sets": ["1890", "1910"]}, "author_link": ["404543", "404537", "404542", "404541", "404538", "404545", "404544", "404539", "404536", "404540"], "item_9_alternative_title_2": {"attribute_name": "その他のタイトル(英)", "attribute_value_mlt": [{"subitem_alternative_title": "The Optical Satellite Tracking System (II)"}]}, "item_9_biblio_info_10": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1974-07", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3_A", "bibliographicPageEnd": "433", "bibliographicPageStart": "406", "bibliographicVolumeNumber": "10", "bibliographic_titles": [{"bibliographic_title": "東京大学宇宙航空研究所報告"}]}]}, "item_9_description_16": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "衛星光学トラッキング装置の詳細を記述する.装置はシュミットカメラ装乳 電気的制御盤,数値制御装置よりなる.シュミットカメラ部はF:1.5,焦点距離75cmで4.2×14.0度の写野を有し,架台は4軸(高度軸,水平軸,追尾軸,極軸)を持ち,衛星観測のトラッキング撮影モード,固定撮影モードに適した構成になっている.電気的制御盤は数値制御装置によりカメラ装置の設定と位置表示を司さどる.", "subitem_description_type": "Abstract"}]}, "item_9_description_17": {"attribute_name": "抄録(英)", "attribute_value_mlt": [{"subitem_description": "The details of the optical satellite tracking system are described. The system consists of the Schmidt camera sub-system, the electrical control console and the numerical control sub-system. The Schmidt camera sub-system has F number of 1.5 and 75 cm focal length, and field of view is 4.2 × 14.0 degrees. The optical mount has the four axes (azimuth, elevation, tracking and polar axes), and is operated in the tracking exposure mode and the fixed exposure mode for scientific satellite observation. The electrical control console is used for setting and indication of the camera with the numerical control sub-system.", "subitem_description_type": "Other"}]}, "item_9_description_18": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "正誤表: 正誤表あり", "subitem_description_type": "Other"}]}, "item_9_description_32": {"attribute_name": "資料番号", "attribute_value_mlt": [{"subitem_description": "資料番号: SA0124404000", "subitem_description_type": "Other"}]}, "item_9_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "東京大学宇宙航空研究所"}]}, "item_9_source_id_21": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0563-8100", "subitem_source_identifier_type": "ISSN"}]}, "item_9_source_id_24": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00161914", "subitem_source_identifier_type": "NCID"}]}, "item_9_text_34": {"attribute_name": "メタデータ提供者", "attribute_value_mlt": [{"subitem_text_value": "メタデータ提供者: ISASNII"}]}, "item_9_text_35": {"attribute_name": "JAXAカテゴリ", "attribute_value_mlt": [{"subitem_text_value": "JAXAカテゴリ: 宇宙科学研究所"}]}, "item_9_text_43": {"attribute_name": "DSpaceコレクション番号", "attribute_value_mlt": [{"subitem_text_value": "DSpaceコレクション番号: 6"}]}, "item_9_text_6": {"attribute_name": "著者所属", "attribute_value_mlt": [{"subitem_text_value": "東京大学宇宙航空研究所"}, {"subitem_text_value": "東京天文台"}, {"subitem_text_value": "東京天文台"}, {"subitem_text_value": "東京大学生産技術研究所"}, {"subitem_text_value": "日本工学工業株式会社"}]}, "item_9_text_7": {"attribute_name": "著者所属(英)", "attribute_value_mlt": [{"subitem_text_language": "en", "subitem_text_value": "Institute of Space and Aeroautical Science University of Tokyo"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "斉藤, 成文"}], "nameIdentifiers": [{"nameIdentifier": "404536", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古在, 由秀"}], "nameIdentifiers": [{"nameIdentifier": "404537", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "富田, 弘一郎"}], "nameIdentifiers": [{"nameIdentifier": "404538", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "長谷部, 望"}], "nameIdentifiers": [{"nameIdentifier": "404539", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高須, 芳雄"}], "nameIdentifiers": [{"nameIdentifier": "404540", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "SAITO, Shigebumi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "404541", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "KOSAI, Yoshihide", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "404542", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "TOMITA, Kouichiro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "404543", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "HASEBE, Nozomu", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "404544", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "TAKASU, Yoshio", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "404545", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-01-23"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "SA0124404.pdf", "filesize": [{"value": "3.3 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 3300000.0, "url": {"label": "SA0124404.pdf", "url": "https://jaxa.repo.nii.ac.jp/record/31502/files/SA0124404.pdf"}, "version_id": "9c344a3d-e3b2-4da0-8a54-93b397fbc1eb"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "科学衛星光学トラッキング装置II", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "科学衛星光学トラッキング装置II"}]}, "item_type_id": "9", "owner": "1", "path": ["1890", "1910"], "permalink_uri": "https://jaxa.repo.nii.ac.jp/records/31502", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-03-26"}, "publish_date": "2015-03-26", "publish_status": "0", "recid": "31502", "relation": {}, "relation_version_is_last": true, "title": ["科学衛星光学トラッキング装置II"], "weko_shared_id": -1}
科学衛星光学トラッキング装置II
https://jaxa.repo.nii.ac.jp/records/31502
https://jaxa.repo.nii.ac.jp/records/3150225af24d5-d884-4d52-9164-2844f56ee18b
名前 / ファイル | ライセンス | アクション |
---|---|---|
SA0124404.pdf (3.3 MB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-03-26 | |||||
タイトル | ||||||
タイトル | 科学衛星光学トラッキング装置II | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
その他のタイトル(英) | ||||||
その他のタイトル | The Optical Satellite Tracking System (II) | |||||
著者 |
斉藤, 成文
× 斉藤, 成文× 古在, 由秀× 富田, 弘一郎× 長谷部, 望× 高須, 芳雄× SAITO, Shigebumi× KOSAI, Yoshihide× TOMITA, Kouichiro× HASEBE, Nozomu× TAKASU, Yoshio |
|||||
著者所属 | ||||||
東京大学宇宙航空研究所 | ||||||
著者所属 | ||||||
東京天文台 | ||||||
著者所属 | ||||||
東京天文台 | ||||||
著者所属 | ||||||
東京大学生産技術研究所 | ||||||
著者所属 | ||||||
日本工学工業株式会社 | ||||||
著者所属(英) | ||||||
en | ||||||
Institute of Space and Aeroautical Science University of Tokyo | ||||||
出版者 | ||||||
出版者 | 東京大学宇宙航空研究所 | |||||
書誌情報 |
東京大学宇宙航空研究所報告 巻 10, 号 3_A, p. 406-433, 発行日 1974-07 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 衛星光学トラッキング装置の詳細を記述する.装置はシュミットカメラ装乳 電気的制御盤,数値制御装置よりなる.シュミットカメラ部はF:1.5,焦点距離75cmで4.2×14.0度の写野を有し,架台は4軸(高度軸,水平軸,追尾軸,極軸)を持ち,衛星観測のトラッキング撮影モード,固定撮影モードに適した構成になっている.電気的制御盤は数値制御装置によりカメラ装置の設定と位置表示を司さどる. | |||||
抄録(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | The details of the optical satellite tracking system are described. The system consists of the Schmidt camera sub-system, the electrical control console and the numerical control sub-system. The Schmidt camera sub-system has F number of 1.5 and 75 cm focal length, and field of view is 4.2 × 14.0 degrees. The optical mount has the four axes (azimuth, elevation, tracking and polar axes), and is operated in the tracking exposure mode and the fixed exposure mode for scientific satellite observation. The electrical control console is used for setting and indication of the camera with the numerical control sub-system. | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 正誤表: 正誤表あり | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0563-8100 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00161914 | |||||
資料番号 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 資料番号: SA0124404000 |