WEKO3
アイテム
{"_buckets": {"deposit": "7c659f03-28fe-4183-a24c-d7aae5fe097e"}, "_deposit": {"created_by": 1, "id": "32297", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "32297"}, "status": "published"}, "_oai": {"id": "oai:jaxa.repo.nii.ac.jp:00032297", "sets": ["1890", "1910"]}, "author_link": ["408203", "408199", "408202", "408204", "408200", "408201"], "item_9_alternative_title_2": {"attribute_name": "その他のタイトル(英)", "attribute_value_mlt": [{"subitem_alternative_title": "\"TANSEI\" Attitude Measurement by Magnetometers and Sun Sensor"}]}, "item_9_biblio_info_10": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1972-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1_B", "bibliographicPageEnd": "129", "bibliographicPageStart": "121", "bibliographicVolumeNumber": "8", "bibliographic_titles": [{"bibliographic_title": "東京大学宇宙航空研究所報告"}]}]}, "item_9_description_17": {"attribute_name": "抄録(英)", "attribute_value_mlt": [{"subitem_description": "The attitude of the experimental satellite \"TANSEI\" (1971-011 A) launched on Febrary, 1971, was measuree utilizing two flux-gate magnetometers and a sun sensor. One magnetometer was loaded in parallel with the satellite\u0027s spin axis and another was parpendicular to the axis. Angle between the axis and the geomagnetic force line is detectable from the outputs of magnetometers. Similarly, angle of the sun is detectable with sun sensor. The orientation of the spin axis is determinated at the position of satellite in space when the calculated orientations of geomagnetic field and the sun are known. As a result, the right ascension of the spin axis orientation was 98~102 degrees and the declination of that was 8~9 degrees in the right ascension-declination coordinate system. And the \"TANSEI\" attitude was very stable without periodic motions as precession. But it leaves something to be improved to measure the attitude. One of the problems is magnetic influence upon the magnetic sensors from another instruments. And it had need improve the attitude sensor or use jointly with another attitude sensor to detect more precisely.", "subitem_description_type": "Other"}]}, "item_9_description_32": {"attribute_name": "資料番号", "attribute_value_mlt": [{"subitem_description": "資料番号: SA0125473000", "subitem_description_type": "Other"}]}, "item_9_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "東京大学宇宙航空研究所"}]}, "item_9_source_id_21": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0563-8100", "subitem_source_identifier_type": "ISSN"}]}, "item_9_source_id_24": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00161914", "subitem_source_identifier_type": "NCID"}]}, "item_9_text_34": {"attribute_name": "メタデータ提供者", "attribute_value_mlt": [{"subitem_text_value": "メタデータ提供者: ISASNII"}]}, "item_9_text_35": {"attribute_name": "JAXAカテゴリ", "attribute_value_mlt": [{"subitem_text_value": "JAXAカテゴリ: 宇宙科学研究所"}]}, "item_9_text_43": {"attribute_name": "DSpaceコレクション番号", "attribute_value_mlt": [{"subitem_text_value": "DSpaceコレクション番号: 6"}]}, "item_9_text_6": {"attribute_name": "著者所属", "attribute_value_mlt": [{"subitem_text_value": "東海大学工学部"}, {"subitem_text_value": "東海大学工学部"}, {"subitem_text_value": "東海大学工学部"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "遠山, 文雄"}], "nameIdentifiers": [{"nameIdentifier": "408199", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "青山, 厳"}], "nameIdentifiers": [{"nameIdentifier": "408200", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高橋, 隆男"}], "nameIdentifiers": [{"nameIdentifier": "408201", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "TOYAMA, Fumio", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "408202", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "AOYAMA, Iwao", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "408203", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "TAKAHASHI, Takao", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "408204", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-01-24"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "SA0125473.pdf", "filesize": [{"value": "455.4 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 455400.0, "url": {"label": "SA0125473.pdf", "url": "https://jaxa.repo.nii.ac.jp/record/32297/files/SA0125473.pdf"}, "version_id": "7ca6b638-0463-4fbf-a5d4-9022ebbf9063"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "地磁気姿勢計による「たんせい」の姿勢測定", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "地磁気姿勢計による「たんせい」の姿勢測定"}]}, "item_type_id": "9", "owner": "1", "path": ["1890", "1910"], "permalink_uri": "https://jaxa.repo.nii.ac.jp/records/32297", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-03-26"}, "publish_date": "2015-03-26", "publish_status": "0", "recid": "32297", "relation": {}, "relation_version_is_last": true, "title": ["地磁気姿勢計による「たんせい」の姿勢測定"], "weko_shared_id": -1}
地磁気姿勢計による「たんせい」の姿勢測定
https://jaxa.repo.nii.ac.jp/records/32297
https://jaxa.repo.nii.ac.jp/records/32297f5705339-5915-48a1-9d5d-6fd1310a2f5d
名前 / ファイル | ライセンス | アクション |
---|---|---|
SA0125473.pdf (455.4 kB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-03-26 | |||||
タイトル | ||||||
タイトル | 地磁気姿勢計による「たんせい」の姿勢測定 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
その他のタイトル(英) | ||||||
その他のタイトル | "TANSEI" Attitude Measurement by Magnetometers and Sun Sensor | |||||
著者 |
遠山, 文雄
× 遠山, 文雄× 青山, 厳× 高橋, 隆男× TOYAMA, Fumio× AOYAMA, Iwao× TAKAHASHI, Takao |
|||||
著者所属 | ||||||
東海大学工学部 | ||||||
著者所属 | ||||||
東海大学工学部 | ||||||
著者所属 | ||||||
東海大学工学部 | ||||||
出版者 | ||||||
出版者 | 東京大学宇宙航空研究所 | |||||
書誌情報 |
東京大学宇宙航空研究所報告 巻 8, 号 1_B, p. 121-129, 発行日 1972-03 |
|||||
抄録(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | The attitude of the experimental satellite "TANSEI" (1971-011 A) launched on Febrary, 1971, was measuree utilizing two flux-gate magnetometers and a sun sensor. One magnetometer was loaded in parallel with the satellite's spin axis and another was parpendicular to the axis. Angle between the axis and the geomagnetic force line is detectable from the outputs of magnetometers. Similarly, angle of the sun is detectable with sun sensor. The orientation of the spin axis is determinated at the position of satellite in space when the calculated orientations of geomagnetic field and the sun are known. As a result, the right ascension of the spin axis orientation was 98~102 degrees and the declination of that was 8~9 degrees in the right ascension-declination coordinate system. And the "TANSEI" attitude was very stable without periodic motions as precession. But it leaves something to be improved to measure the attitude. One of the problems is magnetic influence upon the magnetic sensors from another instruments. And it had need improve the attitude sensor or use jointly with another attitude sensor to detect more precisely. | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0563-8100 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00161914 | |||||
資料番号 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 資料番号: SA0125473000 |