WEKO3
アイテム
{"_buckets": {"deposit": "580bb7de-32ff-401b-9818-0edc532f08ed"}, "_deposit": {"created_by": 1, "id": "37189", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "37189"}, "status": "published"}, "_oai": {"id": "oai:jaxa.repo.nii.ac.jp:00037189", "sets": ["1891", "1915"]}, "author_link": ["479416", "479423", "479422", "479424", "479417", "479415", "479414", "479420", "479418", "479425", "479421", "479419"], "item_5_alternative_title_2": {"attribute_name": "その他のタイトル(英)", "attribute_value_mlt": [{"subitem_alternative_title": "Heat flux measurements in an arc heated flow"}]}, "item_5_biblio_info_10": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1998-01", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "78", "bibliographicPageStart": "67", "bibliographicVolumeNumber": "38", "bibliographic_titles": [{"bibliographic_title": "航空宇宙技術研究所特別資料"}, {"bibliographic_title": "Special Publication of National Aerospace Laboratory", "bibliographic_titleLang": "en"}]}]}, "item_5_description_14": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "22-23 May 1997 (58th). 27-28 Nov. 1997 (59th)", "subitem_description_type": "Other"}]}, "item_5_description_15": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)(英)", "attribute_value_mlt": [{"subitem_description": "22-23 May 1997 (58th). 27-28 Nov. 1997 (59th)", "subitem_description_type": "Other"}]}, "item_5_description_16": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "熱的、化学的非平衡を伴う、アーク加熱された高エンタルピ気流中でのカロリメータによる熱流束の計測は非常に困難を伴う。気相の反応に加えて、プローブの表面状態(触媒性、放射率など)が種々の影響を及ぼす。本報告では、750kWアーク加熱風洞で標準的に使用しているガードンゲージをセンサとして用いたガードン式カロリメータの指示値の妥当性を評価するために、アーク加熱気流計測への適用上の諸問題を検討した。計測原理の異なる熱容量式(スラグ)カロリメータの表面にNi、SiO2などをコーティングして計測した熱流束値との比較により、ガードンゲージは表面特性などの不明確さの範囲内で妥当な結果を与えることがわかった。", "subitem_description_type": "Abstract"}]}, "item_5_description_17": {"attribute_name": "抄録(英)", "attribute_value_mlt": [{"subitem_description": "It accompanies unusual difficulties to measure heat flux with calorimeter in arc heated high enthalpy flow involving thermally and chemically non-equilibrium flow. In that case, specific surface states (catalytic activity, emissivity and so on) of a probe affects various influences in addition to those of gas phase reaction. In this report, several problems when applying Gardon calorimete to arc heated high enthalpy flow is examined, in order to evaluate reasonability of indicated values by Gardon type calorimeter employing usual Gardon gauge used in 750-kW arc heated high enthalpy wind tunnel as a sensor. It was found by comparing heat flux value measured with different principle slug calorimeter of which surface is coated with Ni, SiO2, etc. that the Gardon gauge indicates reasonable results producing less obscurity in the extent of falling in the range of those caused by surface features.", "subitem_description_type": "Other"}]}, "item_5_description_32": {"attribute_name": "資料番号", "attribute_value_mlt": [{"subitem_description": "資料番号: AA0001434007", "subitem_description_type": "Other"}]}, "item_5_description_33": {"attribute_name": "レポート番号", "attribute_value_mlt": [{"subitem_description": "レポート番号: NAL SP-38", "subitem_description_type": "Other"}]}, "item_5_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "航空宇宙技術研究所"}]}, "item_5_publisher_9": {"attribute_name": "出版者(英)", "attribute_value_mlt": [{"subitem_publisher": "National Aerospace Laboratory (NAL)"}]}, "item_5_source_id_21": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0289-260X", "subitem_source_identifier_type": "ISSN"}]}, "item_5_source_id_24": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN10097345", "subitem_source_identifier_type": "NCID"}]}, "item_5_text_35": {"attribute_name": "JAXAカテゴリ", "attribute_value_mlt": [{"subitem_text_value": "JAXAカテゴリ: 航空宇宙技術研究所"}]}, "item_5_text_36": {"attribute_name": "JAXAカテゴリ2", "attribute_value_mlt": [{"subitem_text_value": "JAXAカテゴリ2: AP"}]}, "item_5_text_43": {"attribute_name": "DSpaceコレクション番号", "attribute_value_mlt": [{"subitem_text_value": "DSpaceコレクション番号: 7"}]}, "item_5_text_6": {"attribute_name": "著者所属", "attribute_value_mlt": [{"subitem_text_value": "航空宇宙技術研究所"}, {"subitem_text_value": "航空宇宙技術研究所"}, {"subitem_text_value": "航空宇宙技術研究所"}, {"subitem_text_value": "宇宙開発事業団"}, {"subitem_text_value": "宇宙開発事業団"}, {"subitem_text_value": "AES"}]}, "item_5_text_7": {"attribute_name": "著者所属(英)", "attribute_value_mlt": [{"subitem_text_language": "en", "subitem_text_value": "National Aerospace Laboratory"}, {"subitem_text_language": "en", "subitem_text_value": "National Aerospace Laboratory"}, {"subitem_text_language": "en", "subitem_text_value": "National Aerospace Laboratory"}, {"subitem_text_language": "en", "subitem_text_value": "National Space Development Agency of Japan"}, {"subitem_text_language": "en", "subitem_text_value": "National Space Development Agency of Japan"}, {"subitem_text_language": "en", "subitem_text_value": "Advanced Engineering Services Co Ltd"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "渡辺, 泰夫"}], "nameIdentifiers": [{"nameIdentifier": "479414", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松崎, 貴至"}], "nameIdentifiers": [{"nameIdentifier": "479415", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石田, 清道"}], "nameIdentifiers": [{"nameIdentifier": "479416", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "三保, 和之"}], "nameIdentifiers": [{"nameIdentifier": "479417", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "福井, 利夫"}], "nameIdentifiers": [{"nameIdentifier": "479418", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "濱村, 修"}], "nameIdentifiers": [{"nameIdentifier": "479419", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Watanabe, Yasuo", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "479420", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsuzaki, Takashi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "479421", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ishida, Kiyomichi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "479422", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Miho, Kazuyuki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "479423", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Fukui, Toshio", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "479424", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hamamura, Osamu", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "479425", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-02-10"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "nalsp0038007.pdf", "filesize": [{"value": "995.6 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 995600.0, "url": {"label": "nalsp0038007.pdf", "url": "https://jaxa.repo.nii.ac.jp/record/37189/files/nalsp0038007.pdf"}, "version_id": "69c59454-f31d-418a-be09-85609cea9796"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "高エンタルピ気流", "subitem_subject_scheme": "Other"}, {"subitem_subject": "熱流束", "subitem_subject_scheme": "Other"}, {"subitem_subject": "アーク加熱風洞", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ガードン式カロリメータ", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ガードンゲージ", "subitem_subject_scheme": "Other"}, {"subitem_subject": "アーク加熱気流", "subitem_subject_scheme": "Other"}, {"subitem_subject": "スラグカロリメータ", "subitem_subject_scheme": "Other"}, {"subitem_subject": "表面特性", "subitem_subject_scheme": "Other"}, {"subitem_subject": "カロリメータプローブ", "subitem_subject_scheme": "Other"}, {"subitem_subject": "防熱材", "subitem_subject_scheme": "Other"}, {"subitem_subject": "high enthalpy flow", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "heated flow flux", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "arc heated wind tunnel", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Gardon calorimeter", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Gardon gage", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "arc heated flow", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "slug calorimeter", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "suface characteristic", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "calorimeter prove", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "heat insulation", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "アーク加熱気流の熱流束計測", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "アーク加熱気流の熱流束計測"}]}, "item_type_id": "5", "owner": "1", "path": ["1891", "1915"], "permalink_uri": "https://jaxa.repo.nii.ac.jp/records/37189", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-03-26"}, "publish_date": "2015-03-26", "publish_status": "0", "recid": "37189", "relation": {}, "relation_version_is_last": true, "title": ["アーク加熱気流の熱流束計測"], "weko_shared_id": -1}
アーク加熱気流の熱流束計測
https://jaxa.repo.nii.ac.jp/records/37189
https://jaxa.repo.nii.ac.jp/records/37189555d17b9-f899-4a25-ac46-ec14f7db3821
名前 / ファイル | ライセンス | アクション |
---|---|---|
nalsp0038007.pdf (995.6 kB)
|
|
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-03-26 | |||||
タイトル | ||||||
タイトル | アーク加熱気流の熱流束計測 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 高エンタルピ気流 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 熱流束 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | アーク加熱風洞 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | ガードン式カロリメータ | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | ガードンゲージ | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | アーク加熱気流 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | スラグカロリメータ | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 表面特性 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | カロリメータプローブ | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 防熱材 | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | high enthalpy flow | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | heated flow flux | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | arc heated wind tunnel | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Gardon calorimeter | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Gardon gage | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | arc heated flow | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | slug calorimeter | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | suface characteristic | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | calorimeter prove | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | heat insulation | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
その他のタイトル(英) | ||||||
その他のタイトル | Heat flux measurements in an arc heated flow | |||||
著者 |
渡辺, 泰夫
× 渡辺, 泰夫× 松崎, 貴至× 石田, 清道× 三保, 和之× 福井, 利夫× 濱村, 修× Watanabe, Yasuo× Matsuzaki, Takashi× Ishida, Kiyomichi× Miho, Kazuyuki× Fukui, Toshio× Hamamura, Osamu |
|||||
著者所属 | ||||||
航空宇宙技術研究所 | ||||||
著者所属 | ||||||
航空宇宙技術研究所 | ||||||
著者所属 | ||||||
航空宇宙技術研究所 | ||||||
著者所属 | ||||||
宇宙開発事業団 | ||||||
著者所属 | ||||||
宇宙開発事業団 | ||||||
著者所属 | ||||||
AES | ||||||
著者所属(英) | ||||||
en | ||||||
National Aerospace Laboratory | ||||||
著者所属(英) | ||||||
en | ||||||
National Aerospace Laboratory | ||||||
著者所属(英) | ||||||
en | ||||||
National Aerospace Laboratory | ||||||
著者所属(英) | ||||||
en | ||||||
National Space Development Agency of Japan | ||||||
著者所属(英) | ||||||
en | ||||||
National Space Development Agency of Japan | ||||||
著者所属(英) | ||||||
en | ||||||
Advanced Engineering Services Co Ltd | ||||||
出版者 | ||||||
出版者 | 航空宇宙技術研究所 | |||||
出版者(英) | ||||||
出版者 | National Aerospace Laboratory (NAL) | |||||
書誌情報 |
航空宇宙技術研究所特別資料 en : Special Publication of National Aerospace Laboratory 巻 38, p. 67-78, 発行日 1998-01 |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 22-23 May 1997 (58th). 27-28 Nov. 1997 (59th) | |||||
会議概要(会議名, 開催地, 会期, 主催者等)(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 22-23 May 1997 (58th). 27-28 Nov. 1997 (59th) | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 熱的、化学的非平衡を伴う、アーク加熱された高エンタルピ気流中でのカロリメータによる熱流束の計測は非常に困難を伴う。気相の反応に加えて、プローブの表面状態(触媒性、放射率など)が種々の影響を及ぼす。本報告では、750kWアーク加熱風洞で標準的に使用しているガードンゲージをセンサとして用いたガードン式カロリメータの指示値の妥当性を評価するために、アーク加熱気流計測への適用上の諸問題を検討した。計測原理の異なる熱容量式(スラグ)カロリメータの表面にNi、SiO2などをコーティングして計測した熱流束値との比較により、ガードンゲージは表面特性などの不明確さの範囲内で妥当な結果を与えることがわかった。 | |||||
抄録(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | It accompanies unusual difficulties to measure heat flux with calorimeter in arc heated high enthalpy flow involving thermally and chemically non-equilibrium flow. In that case, specific surface states (catalytic activity, emissivity and so on) of a probe affects various influences in addition to those of gas phase reaction. In this report, several problems when applying Gardon calorimete to arc heated high enthalpy flow is examined, in order to evaluate reasonability of indicated values by Gardon type calorimeter employing usual Gardon gauge used in 750-kW arc heated high enthalpy wind tunnel as a sensor. It was found by comparing heat flux value measured with different principle slug calorimeter of which surface is coated with Ni, SiO2, etc. that the Gardon gauge indicates reasonable results producing less obscurity in the extent of falling in the range of those caused by surface features. | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0289-260X | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN10097345 | |||||
資料番号 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 資料番号: AA0001434007 | |||||
レポート番号 | ||||||
内容記述タイプ | Other | |||||
内容記述 | レポート番号: NAL SP-38 |