WEKO3
アイテム
{"_buckets": {"deposit": "130c35e6-7f1e-4c5e-ab58-107c827d96c9"}, "_deposit": {"created_by": 1, "id": "39952", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "39952"}, "status": "published"}, "_oai": {"id": "oai:jaxa.repo.nii.ac.jp:00039952", "sets": ["1893", "1916"]}, "author_link": ["445732", "445735", "445730", "445729", "445733", "445728", "445734", "445731"], "item_3_alternative_title_2": {"attribute_name": "その他のタイトル(英)", "attribute_value_mlt": [{"subitem_alternative_title": "Technical problems and solutions in replacement of wind tunnel facilities"}]}, "item_3_biblio_info_10": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1997-06", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "19", "bibliographicPageStart": "1", "bibliographicVolumeNumber": "713", "bibliographic_titles": [{"bibliographic_title": "航空宇宙技術研究所資料"}, {"bibliographic_title": "Technical Memorandum of National Aerospace Laboratory", "bibliographic_titleLang": "en"}]}]}, "item_3_description_16": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "1985年の計画から始まった大規模な風洞用設備(遷音速風洞および吹出式風洞に供する設備)の更新は、1995年に終了した。風洞用設備の計画時および更新工事時に既設設備との適合性および設備運用の観点から、調査、検討を行った技術課題や留意事項、ならびに更新工事における解決の実際について報告する。", "subitem_description_type": "Abstract"}]}, "item_3_description_17": {"attribute_name": "抄録(英)", "attribute_value_mlt": [{"subitem_description": "Seven devices related to the NAL wind tunnel facilities were replaced in succession from 1985 to 1995. This paper describes some considerations on the function of each device, the technical problems that occurred, and precautions to be taken in the replacement of wind tunnel facilities.", "subitem_description_type": "Other"}]}, "item_3_description_32": {"attribute_name": "資料番号", "attribute_value_mlt": [{"subitem_description": "資料番号: AA0001068000", "subitem_description_type": "Other"}]}, "item_3_description_33": {"attribute_name": "レポート番号", "attribute_value_mlt": [{"subitem_description": "レポート番号: NAL TM-713", "subitem_description_type": "Other"}]}, "item_3_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "航空宇宙技術研究所"}]}, "item_3_publisher_9": {"attribute_name": "出版者(英)", "attribute_value_mlt": [{"subitem_publisher": "National Aerospace Laboratory (NAL)"}]}, "item_3_source_id_21": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0452-2982", "subitem_source_identifier_type": "ISSN"}]}, "item_3_source_id_24": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00314334", "subitem_source_identifier_type": "NCID"}]}, "item_3_text_35": {"attribute_name": "JAXAカテゴリ", "attribute_value_mlt": [{"subitem_text_value": "JAXAカテゴリ: 航空宇宙技術研究所"}]}, "item_3_text_36": {"attribute_name": "JAXAカテゴリ2", "attribute_value_mlt": [{"subitem_text_value": "JAXAカテゴリ2: AP"}]}, "item_3_text_43": {"attribute_name": "DSpaceコレクション番号", "attribute_value_mlt": [{"subitem_text_value": "DSpaceコレクション番号: 7"}]}, "item_3_text_6": {"attribute_name": "著者所属", "attribute_value_mlt": [{"subitem_text_value": "航空宇宙技術研究所 空力性能部"}, {"subitem_text_value": "航空宇宙技術研究所 空力性能部"}, {"subitem_text_value": "航空宇宙技術研究所 空力性能部"}, {"subitem_text_value": "航空宇宙技術研究所 空力性能部"}]}, "item_3_text_7": {"attribute_name": "著者所属(英)", "attribute_value_mlt": [{"subitem_text_language": "en", "subitem_text_value": "National Aerospace Laboratory Aircraft Aerodynamics Division"}, {"subitem_text_language": "en", "subitem_text_value": "National Aerospace Laboratory Aircraft Aerodynamics Division"}, {"subitem_text_language": "en", "subitem_text_value": "National Aerospace Laboratory Aircraft Aerodynamics Division"}, {"subitem_text_language": "en", "subitem_text_value": "National Aerospace Laboratory Aircraft Aerodynamics Division"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "小松, 行夫"}], "nameIdentifiers": [{"nameIdentifier": "445728", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鈴木, 正光"}], "nameIdentifiers": [{"nameIdentifier": "445729", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "唐沢, 敏夫"}], "nameIdentifiers": [{"nameIdentifier": "445730", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "末永, 尚史"}], "nameIdentifiers": [{"nameIdentifier": "445731", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Komatsu, Yukio", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "445732", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Suzuki, Masamitsu", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "445733", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Karasawa, Toshio", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "445734", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Suenaga, Hisashi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "445735", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-01-27"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "naltm0000713.pdf", "filesize": [{"value": "473.8 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 473800.0, "url": {"label": "naltm0000713.pdf", "url": "https://jaxa.repo.nii.ac.jp/record/39952/files/naltm0000713.pdf"}, "version_id": "e8ff661b-339d-4a7d-92a9-1b9f9894b29a"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "遷音速風洞", "subitem_subject_scheme": "Other"}, {"subitem_subject": "吹出風洞", "subitem_subject_scheme": "Other"}, {"subitem_subject": "風洞設備", "subitem_subject_scheme": "Other"}, {"subitem_subject": "風洞設備計画", "subitem_subject_scheme": "Other"}, {"subitem_subject": "風洞工事計画", "subitem_subject_scheme": "Other"}, {"subitem_subject": "空気圧縮機", "subitem_subject_scheme": "Other"}, {"subitem_subject": "排風機", "subitem_subject_scheme": "Other"}, {"subitem_subject": "吸込管", "subitem_subject_scheme": "Other"}, {"subitem_subject": "冷却器", "subitem_subject_scheme": "Other"}, {"subitem_subject": "電動機", "subitem_subject_scheme": "Other"}, {"subitem_subject": "マンマシーンインターフェース", "subitem_subject_scheme": "Other"}, {"subitem_subject": "transonic wind tunnel", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "blowdown wind tunnel", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "wind tunnel facility", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "wind tunnel facility plan", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "wind tunnel facility construction", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "air compressor", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "exhaust fan", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "suction pipe", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "cooler", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "electric motor", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "man machine interface", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "technical report", "resourceuri": "http://purl.org/coar/resource_type/c_18gh"}]}, "item_title": "風洞設備更新における技術課題と工事", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "風洞設備更新における技術課題と工事"}]}, "item_type_id": "3", "owner": "1", "path": ["1893", "1916"], "permalink_uri": "https://jaxa.repo.nii.ac.jp/records/39952", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-03-26"}, "publish_date": "2015-03-26", "publish_status": "0", "recid": "39952", "relation": {}, "relation_version_is_last": true, "title": ["風洞設備更新における技術課題と工事"], "weko_shared_id": 1}
風洞設備更新における技術課題と工事
https://jaxa.repo.nii.ac.jp/records/39952
https://jaxa.repo.nii.ac.jp/records/399529f2bbb94-7c06-45fc-9a5c-59d78ec4f3fd
名前 / ファイル | ライセンス | アクション |
---|---|---|
naltm0000713.pdf (473.8 kB)
|
|
Item type | テクニカルレポート / Technical Report(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-03-26 | |||||
タイトル | ||||||
タイトル | 風洞設備更新における技術課題と工事 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 遷音速風洞 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 吹出風洞 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 風洞設備 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 風洞設備計画 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 風洞工事計画 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 空気圧縮機 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 排風機 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 吸込管 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 冷却器 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 電動機 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | マンマシーンインターフェース | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | transonic wind tunnel | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | blowdown wind tunnel | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | wind tunnel facility | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | wind tunnel facility plan | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | wind tunnel facility construction | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | air compressor | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | exhaust fan | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | suction pipe | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | cooler | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | electric motor | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | man machine interface | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_18gh | |||||
資源タイプ | technical report | |||||
その他のタイトル(英) | ||||||
その他のタイトル | Technical problems and solutions in replacement of wind tunnel facilities | |||||
著者 |
小松, 行夫
× 小松, 行夫× 鈴木, 正光× 唐沢, 敏夫× 末永, 尚史× Komatsu, Yukio× Suzuki, Masamitsu× Karasawa, Toshio× Suenaga, Hisashi |
|||||
著者所属 | ||||||
航空宇宙技術研究所 空力性能部 | ||||||
著者所属 | ||||||
航空宇宙技術研究所 空力性能部 | ||||||
著者所属 | ||||||
航空宇宙技術研究所 空力性能部 | ||||||
著者所属 | ||||||
航空宇宙技術研究所 空力性能部 | ||||||
著者所属(英) | ||||||
en | ||||||
National Aerospace Laboratory Aircraft Aerodynamics Division | ||||||
著者所属(英) | ||||||
en | ||||||
National Aerospace Laboratory Aircraft Aerodynamics Division | ||||||
著者所属(英) | ||||||
en | ||||||
National Aerospace Laboratory Aircraft Aerodynamics Division | ||||||
著者所属(英) | ||||||
en | ||||||
National Aerospace Laboratory Aircraft Aerodynamics Division | ||||||
出版者 | ||||||
出版者 | 航空宇宙技術研究所 | |||||
出版者(英) | ||||||
出版者 | National Aerospace Laboratory (NAL) | |||||
書誌情報 |
航空宇宙技術研究所資料 en : Technical Memorandum of National Aerospace Laboratory 巻 713, p. 1-19, 発行日 1997-06 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 1985年の計画から始まった大規模な風洞用設備(遷音速風洞および吹出式風洞に供する設備)の更新は、1995年に終了した。風洞用設備の計画時および更新工事時に既設設備との適合性および設備運用の観点から、調査、検討を行った技術課題や留意事項、ならびに更新工事における解決の実際について報告する。 | |||||
抄録(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Seven devices related to the NAL wind tunnel facilities were replaced in succession from 1985 to 1995. This paper describes some considerations on the function of each device, the technical problems that occurred, and precautions to be taken in the replacement of wind tunnel facilities. | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0452-2982 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00314334 | |||||
資料番号 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 資料番号: AA0001068000 | |||||
レポート番号 | ||||||
内容記述タイプ | Other | |||||
内容記述 | レポート番号: NAL TM-713 |