{"_buckets": {"deposit": "95c24d26-c092-4fbb-ac0f-324aba206516"}, "_deposit": {"created_by": 1, "id": "21554", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "21554"}, "status": "published"}, "_oai": {"id": "oai:jaxa.repo.nii.ac.jp:00021554", "sets": ["1888"]}, "author_link": ["202235", "202239", "202241", "202237", "202240", "202238", "202236", "202234"], "item_7_alternative_title_2": {"attribute_name": "その他のタイトル(英)", "attribute_value_mlt": [{"subitem_alternative_title": "Evaluation of High Definition TV images in health care of astronauts"}]}, "item_7_biblio_info_10": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2006-09-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "122", "bibliographicPageStart": "115", "bibliographicVolumeNumber": "43", "bibliographic_titles": [{"bibliographic_title": "宇宙航空環境医学"}, {"bibliographic_title": "Japanese journal of aerospace and environmental medicine", "bibliographic_titleLang": "en"}]}]}, "item_7_description_17": {"attribute_name": "抄録(英)", "attribute_value_mlt": [{"subitem_description": "Japan Aerospace Exploration Agency (JAXA) has a plan to install a High Definition Television (HDTV) system which will be applied to the crew\u0027s healthcare as telemedicine in Japanese Experiment Module (JEM). Prior to the start of JEM operation, JAXA made a contract for experiments of filming on board using a HDTV camera with Russian Space Agency (RSA). The purpose of this feasibility study was to see how we use the HDTV system in space and what kind of medical information we can obtain through HDTV images. Four Russian cosmonauts were assigned to two subjects and two cameramen during the expeditions of #3 and #5 in International Space Station (ISS). They stayed in space for four and six months respectively. Each filming was instructed by a scenario written on the onboard document, and the filmed body portions were frontal face, lateral face, eyes, mouth, teeth, tongue, pharynx, hand and arm. The recorded tapes were delivered to Japan and HDTV images were evaluated by physicians on a Cathode Ray Tube (CRT) monitor. Regarding the quality of HDTV images, 92.7 % of images in the expedition #3 and 97.7 % of images in the expedition #5 were evaluated well in positioning of target. More than 95 % of images in both expeditions were usable in the evaluation about brightness, including slight dark images. In the evaluation about focus, 79.9 % of images in the expedition #3 and 95.8 % of images in the expedition #5 were good. In the medical evaluation, 82.4 % of images in the expedition #3 and 89.4 % in the expedition #5 were judged usable to make a diagnosis. The reason why 3.3 % of images were judged unusable for diagnosis was that they were out of focus or with insufficient brightness. Therefore, the HDTV images can be one of the very useful tools in the crew\u0027s healthcare, if these technical problems are solved by enough crew training or supports from the medical staff on the ground.", "subitem_description_type": "Other"}]}, "item_7_description_32": {"attribute_name": "資料番号", "attribute_value_mlt": [{"subitem_description": "資料番号: DS0049820002", "subitem_description_type": "Other"}]}, "item_7_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Japan Society of Aerospace and environmental Medicine"}]}, "item_7_publisher_9": {"attribute_name": "出版者(英)", "attribute_value_mlt": [{"subitem_publisher": "日本宇宙航空環境医学会"}]}, "item_7_source_id_21": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0387-0723", "subitem_source_identifier_type": "ISSN"}]}, "item_7_source_id_24": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00019323", "subitem_source_identifier_type": "NCID"}]}, "item_7_text_43": {"attribute_name": "DSpaceコレクション番号", "attribute_value_mlt": [{"subitem_text_value": "DSpaceコレクション番号: 7"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "宮本, 晃"}], "nameIdentifiers": [{"nameIdentifier": "202234", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山田, 寛"}], "nameIdentifiers": [{"nameIdentifier": "202235", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松崎, 一葉"}], "nameIdentifiers": [{"nameIdentifier": "202236", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Miyamoto, Akira", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "202237", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamada, Hiroshi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "202238", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsuzaki, Ichiyou", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "202239", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tyurin, Mikhail", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "202240", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Treschev, Sergei", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "202241", "nameIdentifierScheme": "WEKO"}]}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Astronaut, Health care, Telemedicine, HDTV, ISS", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "宇宙飛行士の健康管理を目的としたHDTV映像の評価", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "宇宙飛行士の健康管理を目的としたHDTV映像の評価"}]}, "item_type_id": "7", "owner": "1", "path": ["1888"], "permalink_uri": "https://jaxa.repo.nii.ac.jp/records/21554", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-03-26"}, "publish_date": "2015-03-26", "publish_status": "0", "recid": "21554", "relation": {}, "relation_version_is_last": true, "title": ["宇宙飛行士の健康管理を目的としたHDTV映像の評価"], "weko_shared_id": -1}
宇宙飛行士の健康管理を目的としたHDTV映像の評価
https://jaxa.repo.nii.ac.jp/records/21554
https://jaxa.repo.nii.ac.jp/records/2155498f2ec43-1290-4662-9023-30c19ec39a18
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-03-26 | |||||
タイトル | ||||||
タイトル | 宇宙飛行士の健康管理を目的としたHDTV映像の評価 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Astronaut, Health care, Telemedicine, HDTV, ISS | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
その他のタイトル(英) | ||||||
その他のタイトル | Evaluation of High Definition TV images in health care of astronauts | |||||
著者 |
宮本, 晃
× 宮本, 晃× 山田, 寛× 松崎, 一葉× Miyamoto, Akira× Yamada, Hiroshi× Matsuzaki, Ichiyou× Tyurin, Mikhail× Treschev, Sergei |
|||||
出版者 | ||||||
出版者 | Japan Society of Aerospace and environmental Medicine | |||||
出版者(英) | ||||||
出版者 | 日本宇宙航空環境医学会 | |||||
書誌情報 |
宇宙航空環境医学 en : Japanese journal of aerospace and environmental medicine 巻 43, 号 3, p. 115-122, 発行日 2006-09-01 |
|||||
抄録(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Japan Aerospace Exploration Agency (JAXA) has a plan to install a High Definition Television (HDTV) system which will be applied to the crew's healthcare as telemedicine in Japanese Experiment Module (JEM). Prior to the start of JEM operation, JAXA made a contract for experiments of filming on board using a HDTV camera with Russian Space Agency (RSA). The purpose of this feasibility study was to see how we use the HDTV system in space and what kind of medical information we can obtain through HDTV images. Four Russian cosmonauts were assigned to two subjects and two cameramen during the expeditions of #3 and #5 in International Space Station (ISS). They stayed in space for four and six months respectively. Each filming was instructed by a scenario written on the onboard document, and the filmed body portions were frontal face, lateral face, eyes, mouth, teeth, tongue, pharynx, hand and arm. The recorded tapes were delivered to Japan and HDTV images were evaluated by physicians on a Cathode Ray Tube (CRT) monitor. Regarding the quality of HDTV images, 92.7 % of images in the expedition #3 and 97.7 % of images in the expedition #5 were evaluated well in positioning of target. More than 95 % of images in both expeditions were usable in the evaluation about brightness, including slight dark images. In the evaluation about focus, 79.9 % of images in the expedition #3 and 95.8 % of images in the expedition #5 were good. In the medical evaluation, 82.4 % of images in the expedition #3 and 89.4 % in the expedition #5 were judged usable to make a diagnosis. The reason why 3.3 % of images were judged unusable for diagnosis was that they were out of focus or with insufficient brightness. Therefore, the HDTV images can be one of the very useful tools in the crew's healthcare, if these technical problems are solved by enough crew training or supports from the medical staff on the ground. | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0387-0723 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00019323 | |||||
資料番号 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 資料番号: DS0049820002 |