WEKO3
アイテム
{"_buckets": {"deposit": "86328b68-e7c1-4a1b-9b45-03ffa3fdbbf4"}, "_deposit": {"created_by": 1, "id": "32143", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "32143"}, "status": "published"}, "_oai": {"id": "oai:jaxa.repo.nii.ac.jp:00032143", "sets": ["1890", "1910"]}, "author_link": ["407491", "407492", "407490", "407493", "407488", "407489"], "item_9_alternative_title_2": {"attribute_name": "その他のタイトル(英)", "attribute_value_mlt": [{"subitem_alternative_title": "On an Adaptable Miniature Pressure Transducer"}]}, "item_9_biblio_info_10": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1973-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1_A", "bibliographicPageEnd": "111", "bibliographicPageStart": "94", "bibliographicVolumeNumber": "9", "bibliographic_titles": [{"bibliographic_title": "東京大学宇宙航空研究所報告"}]}]}, "item_9_description_16": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "流体機械の回転翼または振動翼まわりの流れを解析するために,翼面上の表面圧を測定すべくバルク半導体ひずみゲージを用いた小型の示圧計を試作した.それは翼面上の任意の場所に直接貼付できるよう,外径4φmm,厚さ0.4mmという最小寸法につくられている.またこの示圧計は,回転円柱表面の変動圧を測定出来るにたりるだけの高感度(~2.5×10^\u003c-1\u003emmAq)と高レスポンス(200~1,000Hzの応答周波数)を持っている.本論文には小圧計の構造と特性の概要を示すと共に,若干のル用例がのべてある.", "subitem_description_type": "Abstract"}]}, "item_9_description_17": {"attribute_name": "抄録(英)", "attribute_value_mlt": [{"subitem_description": "To analyse behavior of flow around a rotating or oscillating blade in turbomachine, the authors have developed a miniature pressure transducer using a pair of bulk semi-conductor strain gauge to measure the surface pressure on the blade or wall. The device, which is produced in the least size of 4 φmm in diameter and ~0.4 mm in thickness to be adaptable easily and directly to an arbitrary spot on the moving surface, has high sensitibity ... ~2.5×10^\u003c-6\u003e/mmAq ... and high response ... 200~1,000 Hz ... enough to permit measuring the fluctuating pressure on a rotating cylinder or oscillating blade surface. This paper outlines construction and characteristics of the pressure transducer along with a few applications.", "subitem_description_type": "Other"}]}, "item_9_description_32": {"attribute_name": "資料番号", "attribute_value_mlt": [{"subitem_description": "資料番号: SA0125275000", "subitem_description_type": "Other"}]}, "item_9_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "東京大学宇宙航空研究所"}]}, "item_9_source_id_21": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0563-8100", "subitem_source_identifier_type": "ISSN"}]}, "item_9_source_id_24": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00161914", "subitem_source_identifier_type": "NCID"}]}, "item_9_text_34": {"attribute_name": "メタデータ提供者", "attribute_value_mlt": [{"subitem_text_value": "メタデータ提供者: ISASNII"}]}, "item_9_text_35": {"attribute_name": "JAXAカテゴリ", "attribute_value_mlt": [{"subitem_text_value": "JAXAカテゴリ: 宇宙科学研究所"}]}, "item_9_text_43": {"attribute_name": "DSpaceコレクション番号", "attribute_value_mlt": [{"subitem_text_value": "DSpaceコレクション番号: 6"}]}, "item_9_text_6": {"attribute_name": "著者所属", "attribute_value_mlt": [{"subitem_text_value": "東京大学宇宙航空研究所"}, {"subitem_text_value": "東京大学宇宙航空研究所"}, {"subitem_text_value": "東京大学宇宙航空研究所"}]}, "item_9_text_7": {"attribute_name": "著者所属(英)", "attribute_value_mlt": [{"subitem_text_language": "en", "subitem_text_value": "Institute of Space and Aeronautical Science University of Tokyo"}, {"subitem_text_language": "en", "subitem_text_value": "Institute of Space and Aeronautical Science University of Tokyo"}, {"subitem_text_language": "en", "subitem_text_value": "Institute of Space and Aeronautical Science University of Tokyo"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "浅沼, 強"}], "nameIdentifiers": [{"nameIdentifier": "407488", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高久, 有幹"}], "nameIdentifiers": [{"nameIdentifier": "407489", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "谷勝, 達哉"}], "nameIdentifiers": [{"nameIdentifier": "407490", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "ASANUMA, Tsuyoshi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "407491", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "TAKAKU, Aritomo", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "407492", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "TANIKATSU, Tatsuya", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "407493", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-01-24"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "SA0125275.pdf", "filesize": [{"value": "1.5 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1500000.0, "url": {"label": "SA0125275.pdf", "url": "https://jaxa.repo.nii.ac.jp/record/32143/files/SA0125275.pdf"}, "version_id": "857c0067-7e09-42f1-8d70-b6bb7d08f6fe"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "貼付式小型示圧計", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "貼付式小型示圧計"}]}, "item_type_id": "9", "owner": "1", "path": ["1890", "1910"], "permalink_uri": "https://jaxa.repo.nii.ac.jp/records/32143", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-03-26"}, "publish_date": "2015-03-26", "publish_status": "0", "recid": "32143", "relation": {}, "relation_version_is_last": true, "title": ["貼付式小型示圧計"], "weko_shared_id": -1}
貼付式小型示圧計
https://jaxa.repo.nii.ac.jp/records/32143
https://jaxa.repo.nii.ac.jp/records/32143eb069e8d-97b8-4099-8014-02926dc0fbcb
名前 / ファイル | ライセンス | アクション |
---|---|---|
SA0125275.pdf (1.5 MB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-03-26 | |||||
タイトル | ||||||
タイトル | 貼付式小型示圧計 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
その他のタイトル(英) | ||||||
その他のタイトル | On an Adaptable Miniature Pressure Transducer | |||||
著者 |
浅沼, 強
× 浅沼, 強× 高久, 有幹× 谷勝, 達哉× ASANUMA, Tsuyoshi× TAKAKU, Aritomo× TANIKATSU, Tatsuya |
|||||
著者所属 | ||||||
東京大学宇宙航空研究所 | ||||||
著者所属 | ||||||
東京大学宇宙航空研究所 | ||||||
著者所属 | ||||||
東京大学宇宙航空研究所 | ||||||
著者所属(英) | ||||||
en | ||||||
Institute of Space and Aeronautical Science University of Tokyo | ||||||
著者所属(英) | ||||||
en | ||||||
Institute of Space and Aeronautical Science University of Tokyo | ||||||
著者所属(英) | ||||||
en | ||||||
Institute of Space and Aeronautical Science University of Tokyo | ||||||
出版者 | ||||||
出版者 | 東京大学宇宙航空研究所 | |||||
書誌情報 |
東京大学宇宙航空研究所報告 巻 9, 号 1_A, p. 94-111, 発行日 1973-01 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 流体機械の回転翼または振動翼まわりの流れを解析するために,翼面上の表面圧を測定すべくバルク半導体ひずみゲージを用いた小型の示圧計を試作した.それは翼面上の任意の場所に直接貼付できるよう,外径4φmm,厚さ0.4mmという最小寸法につくられている.またこの示圧計は,回転円柱表面の変動圧を測定出来るにたりるだけの高感度(~2.5×10^<-1>mmAq)と高レスポンス(200~1,000Hzの応答周波数)を持っている.本論文には小圧計の構造と特性の概要を示すと共に,若干のル用例がのべてある. | |||||
抄録(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | To analyse behavior of flow around a rotating or oscillating blade in turbomachine, the authors have developed a miniature pressure transducer using a pair of bulk semi-conductor strain gauge to measure the surface pressure on the blade or wall. The device, which is produced in the least size of 4 φmm in diameter and ~0.4 mm in thickness to be adaptable easily and directly to an arbitrary spot on the moving surface, has high sensitibity ... ~2.5×10^<-6>/mmAq ... and high response ... 200~1,000 Hz ... enough to permit measuring the fluctuating pressure on a rotating cylinder or oscillating blade surface. This paper outlines construction and characteristics of the pressure transducer along with a few applications. | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0563-8100 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00161914 | |||||
資料番号 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 資料番号: SA0125275000 |