WEKO3
アイテム
{"_buckets": {"deposit": "88df9a0e-a783-4eaa-8fb3-87cf92f2cec6"}, "_deposit": {"created_by": 1, "id": "32551", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "32551"}, "status": "published"}, "_oai": {"id": "oai:jaxa.repo.nii.ac.jp:00032551", "sets": ["1890", "1910"]}, "author_link": ["409983", "409982", "409981", "409985", "409984", "409986"], "item_9_alternative_title_2": {"attribute_name": "その他のタイトル(英)", "attribute_value_mlt": [{"subitem_alternative_title": "Variably-Humidified Air Flow Combustion Facilities"}]}, "item_9_biblio_info_10": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1980-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1_C", "bibliographicPageEnd": "613", "bibliographicPageStart": "587", "bibliographicVolumeNumber": "16", "bibliographic_titles": [{"bibliographic_title": "東京大学宇宙航空研究所報告"}]}]}, "item_9_description_16": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "燃焼に及ぼす酸化剤中の水蒸気濃度の影響を研究する目的で,可変湿度空気流燃焼実験装置を設備した.制御可能な水蒸気濃度は,常圧でモル分率にして0.001~0.1の範囲であり,供給しうる最大乾き空気流量は0.17kg/sである.本装置では空気を十分に加湿した後に,脱湿過程で水蒸気濃度を制御する方法を用いている.加湿は空気と水との接触により行われ,脱湿方法としては,冷却による脱湿方法と膨張による脱湿方法とを用いている.本報告には,装置の設計方針,装置の詳細および性能試験の結果が述べられている.", "subitem_description_type": "Abstract"}]}, "item_9_description_17": {"attribute_name": "抄録(英)", "attribute_value_mlt": [{"subitem_description": "Variably-Humidified Air Flow Combustion Facilities have been constructed for the study of the effect of the water-vapor concentration in the oxidizer on combustions. The controllable range of the water-vapor concentration is 0.001~0.1 in mole fraction at a total pressure of atmospheric; the maximum mass flow-rate of the dry air is 0.17 kg/s. The air is first excessively humidified and then dehumidified to a desired humidity. Humidifying is made by contact of the air with the liquid water surface. Dehumidifying is achieved principally by the contact cooling method and supplementarily by the expansion method. Design principles, detailed specifications of the apparatus, and the results of the performance tests are described.", "subitem_description_type": "Other"}]}, "item_9_description_32": {"attribute_name": "資料番号", "attribute_value_mlt": [{"subitem_description": "資料番号: SA0125856000", "subitem_description_type": "Other"}]}, "item_9_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "東京大学宇宙航空研究所"}]}, "item_9_source_id_21": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0563-8100", "subitem_source_identifier_type": "ISSN"}]}, "item_9_source_id_24": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00161914", "subitem_source_identifier_type": "NCID"}]}, "item_9_text_34": {"attribute_name": "メタデータ提供者", "attribute_value_mlt": [{"subitem_text_value": "メタデータ提供者: ISASNII"}]}, "item_9_text_35": {"attribute_name": "JAXAカテゴリ", "attribute_value_mlt": [{"subitem_text_value": "JAXAカテゴリ: 宇宙科学研究所"}]}, "item_9_text_43": {"attribute_name": "DSpaceコレクション番号", "attribute_value_mlt": [{"subitem_text_value": "DSpaceコレクション番号: 6"}]}, "item_9_text_6": {"attribute_name": "著者所属", "attribute_value_mlt": [{"subitem_text_value": "東京大学宇宙航空所究所"}, {"subitem_text_value": "東京大学宇宙航空所究所"}, {"subitem_text_value": "東京大学宇宙航空所究所"}]}, "item_9_text_7": {"attribute_name": "著者所属(英)", "attribute_value_mlt": [{"subitem_text_language": "en", "subitem_text_value": "Institute of Space and Aeronautical Science, University of Tokyo"}, {"subitem_text_language": "en", "subitem_text_value": "Institute of Space and Aeronautical Science, University of Tokyo"}, {"subitem_text_language": "en", "subitem_text_value": "Institute of Space and Aeronautical Science, University of Tokyo"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "辻, 廣"}], "nameIdentifiers": [{"nameIdentifier": "409981", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松井, 潔"}], "nameIdentifiers": [{"nameIdentifier": "409982", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "牧野, 敦"}], "nameIdentifiers": [{"nameIdentifier": "409983", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "TSUJI, Hiroshi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "409984", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "MATSUI, Kiyoshi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "409985", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "MAKINO, Atsushi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "409986", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-01-24"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "SA0125856.pdf", "filesize": [{"value": "1.5 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1500000.0, "url": {"label": "SA0125856.pdf", "url": "https://jaxa.repo.nii.ac.jp/record/32551/files/SA0125856.pdf"}, "version_id": "1b376109-3e6e-4c8f-92d1-d07a66b7f364"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "\u003c論文\u003e可変湿度空気流燃焼実験装置", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "\u003c論文\u003e可変湿度空気流燃焼実験装置"}]}, "item_type_id": "9", "owner": "1", "path": ["1890", "1910"], "permalink_uri": "https://jaxa.repo.nii.ac.jp/records/32551", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-03-26"}, "publish_date": "2015-03-26", "publish_status": "0", "recid": "32551", "relation": {}, "relation_version_is_last": true, "title": ["\u003c論文\u003e可変湿度空気流燃焼実験装置"], "weko_shared_id": -1}
<論文>可変湿度空気流燃焼実験装置
https://jaxa.repo.nii.ac.jp/records/32551
https://jaxa.repo.nii.ac.jp/records/32551856e2e21-2fc2-4bd7-919f-9774cc90870b
名前 / ファイル | ライセンス | アクション |
---|---|---|
SA0125856.pdf (1.5 MB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-03-26 | |||||
タイトル | ||||||
タイトル | <論文>可変湿度空気流燃焼実験装置 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
その他のタイトル(英) | ||||||
その他のタイトル | Variably-Humidified Air Flow Combustion Facilities | |||||
著者 |
辻, 廣
× 辻, 廣× 松井, 潔× 牧野, 敦× TSUJI, Hiroshi× MATSUI, Kiyoshi× MAKINO, Atsushi |
|||||
著者所属 | ||||||
東京大学宇宙航空所究所 | ||||||
著者所属 | ||||||
東京大学宇宙航空所究所 | ||||||
著者所属 | ||||||
東京大学宇宙航空所究所 | ||||||
著者所属(英) | ||||||
en | ||||||
Institute of Space and Aeronautical Science, University of Tokyo | ||||||
著者所属(英) | ||||||
en | ||||||
Institute of Space and Aeronautical Science, University of Tokyo | ||||||
著者所属(英) | ||||||
en | ||||||
Institute of Space and Aeronautical Science, University of Tokyo | ||||||
出版者 | ||||||
出版者 | 東京大学宇宙航空研究所 | |||||
書誌情報 |
東京大学宇宙航空研究所報告 巻 16, 号 1_C, p. 587-613, 発行日 1980-03 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 燃焼に及ぼす酸化剤中の水蒸気濃度の影響を研究する目的で,可変湿度空気流燃焼実験装置を設備した.制御可能な水蒸気濃度は,常圧でモル分率にして0.001~0.1の範囲であり,供給しうる最大乾き空気流量は0.17kg/sである.本装置では空気を十分に加湿した後に,脱湿過程で水蒸気濃度を制御する方法を用いている.加湿は空気と水との接触により行われ,脱湿方法としては,冷却による脱湿方法と膨張による脱湿方法とを用いている.本報告には,装置の設計方針,装置の詳細および性能試験の結果が述べられている. | |||||
抄録(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Variably-Humidified Air Flow Combustion Facilities have been constructed for the study of the effect of the water-vapor concentration in the oxidizer on combustions. The controllable range of the water-vapor concentration is 0.001~0.1 in mole fraction at a total pressure of atmospheric; the maximum mass flow-rate of the dry air is 0.17 kg/s. The air is first excessively humidified and then dehumidified to a desired humidity. Humidifying is made by contact of the air with the liquid water surface. Dehumidifying is achieved principally by the contact cooling method and supplementarily by the expansion method. Design principles, detailed specifications of the apparatus, and the results of the performance tests are described. | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0563-8100 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00161914 | |||||
資料番号 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 資料番号: SA0125856000 |