{"_buckets": {"deposit": "c4fa57e7-66bd-46f0-bcca-c97375408244"}, "_deposit": {"created_by": 1, "id": "40615", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "40615"}, "status": "published"}, "_oai": {"id": "oai:jaxa.repo.nii.ac.jp:00040615", "sets": ["1893", "1917"]}, "author_link": ["448890", "448895", "448888", "448886", "448889", "448896", "448887", "448893", "448897", "448894", "448891", "448892"], "item_3_alternative_title_2": {"attribute_name": "その他のタイトル(英)", "attribute_value_mlt": [{"subitem_alternative_title": "Heat flux measurements by a slug calorimeter in an arc heated flow"}]}, "item_3_biblio_info_10": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1999-06", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "9", "bibliographicPageStart": "1", "bibliographicVolumeNumber": "1388", "bibliographic_titles": [{"bibliographic_title": "航空宇宙技術研究所報告"}, {"bibliographic_title": "Technical Report of National Aerospace Laboratory", "bibliographic_titleLang": "en"}]}]}, "item_3_description_16": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "集中熱容量式(スラグ)カロリメータにより、750kWアーク加熱風洞気流の熱流束を計測した。銅製のスラグ表面には、種々の触媒特性のコーティングを実施し、その熱流束値への効果を調べた。熱流束値は、Cu、Niなどの金属表面で大きく、SiOなどのガラス質非触媒性表面では極めて小さいことが確認され、その序列は文献値と一致した。熱流束計測値は、ガードン式カロリメータの結果とオーダーで一致し、その平均的値のガードン計測値からの偏差は倍数1.8程度に収まった。この差違は、計測面積の相違、表面状態の不明確さ、流れ場の不均一などに由来すると推定される。", "subitem_description_type": "Abstract"}]}, "item_3_description_17": {"attribute_name": "抄録(英)", "attribute_value_mlt": [{"subitem_description": "This paper shows the application of a slug type calorimeter to the heat flux measurements of an arc-heated flow, and evaluates the effect of slug surface coatings with differing catalytic efficiency on measured heat flux. Metallic coatings are more catalytic and result in higher heat flux values than coating containing silica. These results are in accordance with the known order of catalytic effectiveness. Measured heat flux values agree in magnitude and lie within a factor of 1.8 of the values obtained by Gardon type calorimeters. Presumed sources of the difference are the difference in sensing areas, ambiguity of surface characteristics, and flow field nonuniformity.", "subitem_description_type": "Other"}]}, "item_3_description_32": {"attribute_name": "資料番号", "attribute_value_mlt": [{"subitem_description": "資料番号: AA0001979000", "subitem_description_type": "Other"}]}, "item_3_description_33": {"attribute_name": "レポート番号", "attribute_value_mlt": [{"subitem_description": "レポート番号: NAL TR-1388", "subitem_description_type": "Other"}]}, "item_3_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "航空宇宙技術研究所"}]}, "item_3_publisher_9": {"attribute_name": "出版者(英)", "attribute_value_mlt": [{"subitem_publisher": "National Aerospace Laboratory (NAL)"}]}, "item_3_source_id_21": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0389-4010", "subitem_source_identifier_type": "ISSN"}]}, "item_3_text_35": {"attribute_name": "JAXAカテゴリ", "attribute_value_mlt": [{"subitem_text_value": "JAXAカテゴリ: 航空宇宙技術研究所"}]}, "item_3_text_36": {"attribute_name": "JAXAカテゴリ2", "attribute_value_mlt": [{"subitem_text_value": "JAXAカテゴリ2: AP"}]}, "item_3_text_43": {"attribute_name": "DSpaceコレクション番号", "attribute_value_mlt": [{"subitem_text_value": "DSpaceコレクション番号: 7"}]}, "item_3_text_6": {"attribute_name": "著者所属", "attribute_value_mlt": [{"subitem_text_value": "航空宇宙技術研究所 流体科学総合研究グループ"}, {"subitem_text_value": "航空宇宙技術研究所 流体科学総合研究グループ"}, {"subitem_text_value": "航空宇宙技術研究所 流体科学総合研究グループ"}, {"subitem_text_value": "宇宙開発事業団"}, {"subitem_text_value": "宇宙開発事業団"}, {"subitem_text_value": "エイ・イー・エス"}]}, "item_3_text_7": {"attribute_name": "著者所属(英)", "attribute_value_mlt": [{"subitem_text_language": "en", "subitem_text_value": "National Aerospace Laboratory Fluid Science Research Center"}, {"subitem_text_language": "en", "subitem_text_value": "National Aerospace Laboratory Fluid Science Research Center"}, {"subitem_text_language": "en", "subitem_text_value": "National Aerospace Laboratory Fluid Science Research Center"}, {"subitem_text_language": "en", "subitem_text_value": "National Space Development Agency of Japan"}, {"subitem_text_language": "en", "subitem_text_value": "National Space Development Agency of Japan"}, {"subitem_text_language": "en", "subitem_text_value": "Advanced Engineering Services Co Ltd"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "渡辺, 泰夫"}], "nameIdentifiers": [{"nameIdentifier": "448886", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松崎, 貴至"}], "nameIdentifiers": [{"nameIdentifier": "448887", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石田, 清道"}], "nameIdentifiers": [{"nameIdentifier": "448888", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "三保, 和之"}], "nameIdentifiers": [{"nameIdentifier": "448889", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "福井, 利夫"}], "nameIdentifiers": [{"nameIdentifier": "448890", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "濱村, 修"}], "nameIdentifiers": [{"nameIdentifier": "448891", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Watanabe, Yasuo", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "448892", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsuzaki, Takashi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "448893", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ishida, Kiyomichi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "448894", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Miho, Kazuyuki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "448895", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Fukui, Toshio", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "448896", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hamamura, Osamu", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "448897", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-01-27"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "naltr0001388.pdf", "filesize": [{"value": "182.4 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 182400.0, "url": {"label": "naltr0001388.pdf", "url": "https://jaxa.repo.nii.ac.jp/record/40615/files/naltr0001388.pdf"}, "version_id": "adb37eb0-8f1b-472d-82aa-c551c28c07e9"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "アーク加熱気流", "subitem_subject_scheme": "Other"}, {"subitem_subject": "熱流束計測", "subitem_subject_scheme": "Other"}, {"subitem_subject": "スラグ型カロリメータ", "subitem_subject_scheme": "Other"}, {"subitem_subject": "高エンタルピー流", "subitem_subject_scheme": "Other"}, {"subitem_subject": "触媒効果", "subitem_subject_scheme": "Other"}, {"subitem_subject": "風洞実験", "subitem_subject_scheme": "Other"}, {"subitem_subject": "アーク加熱風洞", "subitem_subject_scheme": "Other"}, {"subitem_subject": "スラグ表面コーティング", "subitem_subject_scheme": "Other"}, {"subitem_subject": "熱伝達", "subitem_subject_scheme": "Other"}, {"subitem_subject": "arc heated flow", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "heat flux measurement", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "slug type calorimeter", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "high enthalpy flow", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "catalytic effect", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "wind tunnel experiment", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "arc heated wind tunnel", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "slug surface coating", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "heat transfer", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "technical report", "resourceuri": "http://purl.org/coar/resource_type/c_18gh"}]}, "item_title": "集中熱容量式(スラグ)カロリメータによるアーク加熱気流の熱流束計測", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "集中熱容量式(スラグ)カロリメータによるアーク加熱気流の熱流束計測"}]}, "item_type_id": "3", "owner": "1", "path": ["1893", "1917"], "permalink_uri": "https://jaxa.repo.nii.ac.jp/records/40615", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-03-26"}, "publish_date": "2015-03-26", "publish_status": "0", "recid": "40615", "relation": {}, "relation_version_is_last": true, "title": ["集中熱容量式(スラグ)カロリメータによるアーク加熱気流の熱流束計測"], "weko_shared_id": 1}
集中熱容量式(スラグ)カロリメータによるアーク加熱気流の熱流束計測
https://jaxa.repo.nii.ac.jp/records/40615
https://jaxa.repo.nii.ac.jp/records/40615eb84d868-7406-48af-9eae-54aa18e376c4
名前 / ファイル | ライセンス | アクション |
---|---|---|
naltr0001388.pdf (182.4 kB)
|
|
Item type | テクニカルレポート / Technical Report(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-03-26 | |||||
タイトル | ||||||
タイトル | 集中熱容量式(スラグ)カロリメータによるアーク加熱気流の熱流束計測 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | アーク加熱気流 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 熱流束計測 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | スラグ型カロリメータ | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 高エンタルピー流 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 触媒効果 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 風洞実験 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | アーク加熱風洞 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | スラグ表面コーティング | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 熱伝達 | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | arc heated flow | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | heat flux measurement | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | slug type calorimeter | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | high enthalpy flow | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | catalytic effect | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | wind tunnel experiment | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | arc heated wind tunnel | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | slug surface coating | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | heat transfer | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_18gh | |||||
資源タイプ | technical report | |||||
その他のタイトル(英) | ||||||
その他のタイトル | Heat flux measurements by a slug calorimeter in an arc heated flow | |||||
著者 |
渡辺, 泰夫
× 渡辺, 泰夫× 松崎, 貴至× 石田, 清道× 三保, 和之× 福井, 利夫× 濱村, 修× Watanabe, Yasuo× Matsuzaki, Takashi× Ishida, Kiyomichi× Miho, Kazuyuki× Fukui, Toshio× Hamamura, Osamu |
|||||
著者所属 | ||||||
航空宇宙技術研究所 流体科学総合研究グループ | ||||||
著者所属 | ||||||
航空宇宙技術研究所 流体科学総合研究グループ | ||||||
著者所属 | ||||||
航空宇宙技術研究所 流体科学総合研究グループ | ||||||
著者所属 | ||||||
宇宙開発事業団 | ||||||
著者所属 | ||||||
宇宙開発事業団 | ||||||
著者所属 | ||||||
エイ・イー・エス | ||||||
著者所属(英) | ||||||
en | ||||||
National Aerospace Laboratory Fluid Science Research Center | ||||||
著者所属(英) | ||||||
en | ||||||
National Aerospace Laboratory Fluid Science Research Center | ||||||
著者所属(英) | ||||||
en | ||||||
National Aerospace Laboratory Fluid Science Research Center | ||||||
著者所属(英) | ||||||
en | ||||||
National Space Development Agency of Japan | ||||||
著者所属(英) | ||||||
en | ||||||
National Space Development Agency of Japan | ||||||
著者所属(英) | ||||||
en | ||||||
Advanced Engineering Services Co Ltd | ||||||
出版者 | ||||||
出版者 | 航空宇宙技術研究所 | |||||
出版者(英) | ||||||
出版者 | National Aerospace Laboratory (NAL) | |||||
書誌情報 |
航空宇宙技術研究所報告 en : Technical Report of National Aerospace Laboratory 巻 1388, p. 1-9, 発行日 1999-06 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 集中熱容量式(スラグ)カロリメータにより、750kWアーク加熱風洞気流の熱流束を計測した。銅製のスラグ表面には、種々の触媒特性のコーティングを実施し、その熱流束値への効果を調べた。熱流束値は、Cu、Niなどの金属表面で大きく、SiOなどのガラス質非触媒性表面では極めて小さいことが確認され、その序列は文献値と一致した。熱流束計測値は、ガードン式カロリメータの結果とオーダーで一致し、その平均的値のガードン計測値からの偏差は倍数1.8程度に収まった。この差違は、計測面積の相違、表面状態の不明確さ、流れ場の不均一などに由来すると推定される。 | |||||
抄録(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | This paper shows the application of a slug type calorimeter to the heat flux measurements of an arc-heated flow, and evaluates the effect of slug surface coatings with differing catalytic efficiency on measured heat flux. Metallic coatings are more catalytic and result in higher heat flux values than coating containing silica. These results are in accordance with the known order of catalytic effectiveness. Measured heat flux values agree in magnitude and lie within a factor of 1.8 of the values obtained by Gardon type calorimeters. Presumed sources of the difference are the difference in sensing areas, ambiguity of surface characteristics, and flow field nonuniformity. | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0389-4010 | |||||
資料番号 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 資料番号: AA0001979000 | |||||
レポート番号 | ||||||
内容記述タイプ | Other | |||||
内容記述 | レポート番号: NAL TR-1388 |