WEKO3
アイテム
{"_buckets": {"deposit": "7ada88e8-b360-4175-82d9-49327f3e4e5c"}, "_deposit": {"created_by": 1, "id": "5856", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "5856"}, "status": "published"}, "_oai": {"id": "oai:jaxa.repo.nii.ac.jp:00005856", "sets": ["1017", "1891"]}, "author_link": ["28852", "28851"], "item_5_alternative_title_2": {"attribute_name": "その他のタイトル(英)", "attribute_value_mlt": [{"subitem_alternative_title": "Research and development of high sensitivity camera tube HARP and its application"}]}, "item_5_biblio_info_10": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2006-11-16", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "13", "bibliographicPageStart": "2", "bibliographicVolumeNumber": "JAXA-SP-06-017", "bibliographic_titles": [{"bibliographic_title": "宇宙航空研究開発機構特別資料: 第2回学際領域における分子イメージングフォーラム"}, {"bibliographic_title": "JAXA Special Publication: Proceedings of the 2nd Interdisciplinary Forum on Molecular Imaging", "bibliographic_titleLang": "en"}]}]}, "item_5_description_16": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "撮像デバイスは、その感度が高ければ高いほど、暗い被写体でもより鮮明な映像として捉えることができる。このため、約80年の歴史を持つ撮像デバイスの研究においてもその高感度化は常に最重要テーマとして位置づけられてきた。当所でも1980年代の初頭に、超高感度と高画質の両立を可能とする新たな撮像デバイスの研究に着手した。その結果、1985年、光導電型撮像管のアモルファスセレン(a-Se)のターゲット(光電変換膜)を約10(exp 8)V/mの強電界で動作させた場合、アバランシェ増倍(電子なだれ増倍)現象が安定に連続して生じ、画質が良好な状態で極めて高い感度が得られることを見出した。これを基にHARP(High-gain Avalanche Rushing amorphous Photoconductor)とよばれる超高感度・高画質撮像管を開発、実用化した。HARP撮像管は、夜間緊急報道やオーロラ、夜行性動物の撮影などの放送用のみならず、深海探査研究やガンの早期発見などを目的としたX線医療診断の研究、新薬の開発などを目指した国のバイオ研究など、種々の分野の先端研究で活用されている。本稿では、HARP撮像管の発明の経緯と、今日までの長年の研究取り組みで高性能化が図られた超高感度HARP撮像管の特性を述べるとともに、この撮像技術によるさまざまな分野への応用を紹介する。", "subitem_description_type": "Abstract"}]}, "item_5_description_32": {"attribute_name": "資料番号", "attribute_value_mlt": [{"subitem_description": "資料番号: AA0063158001", "subitem_description_type": "Other"}]}, "item_5_description_33": {"attribute_name": "レポート番号", "attribute_value_mlt": [{"subitem_description": "レポート番号: JAXA-SP-06-017", "subitem_description_type": "Other"}]}, "item_5_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "宇宙航空研究開発機構"}]}, "item_5_publisher_9": {"attribute_name": "出版者(英)", "attribute_value_mlt": [{"subitem_publisher": "Japan Aerospace Exploration Agency (JAXA)"}]}, "item_5_source_id_21": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1349-113X", "subitem_source_identifier_type": "ISSN"}]}, "item_5_source_id_24": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA11984031", "subitem_source_identifier_type": "NCID"}]}, "item_5_text_20": {"attribute_name": "その他キーワード", "attribute_value_mlt": [{"subitem_text_value": "計装(計測制御装置の装備技術)及び写真技術"}, {"subitem_text_value": "電子及び電気工学"}]}, "item_5_text_35": {"attribute_name": "JAXAカテゴリ", "attribute_value_mlt": [{"subitem_text_value": "JAXAカテゴリ: 特別資料"}]}, "item_5_text_40": {"attribute_name": "jaxa出版物種類", "attribute_value_mlt": [{"subitem_text_value": "jaxa出版物種類: SP"}]}, "item_5_text_43": {"attribute_name": "DSpaceコレクション番号", "attribute_value_mlt": [{"subitem_text_value": "DSpaceコレクション番号: 7"}]}, "item_5_text_6": {"attribute_name": "著者所属", "attribute_value_mlt": [{"subitem_text_value": "日本放送協会"}]}, "item_5_text_7": {"attribute_name": "著者所属(英)", "attribute_value_mlt": [{"subitem_text_language": "en", "subitem_text_value": "Japan Broadcasting Corporation"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "谷岡, 健吉"}], "nameIdentifiers": [{"nameIdentifier": "28851", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tanioka, Kenkichi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "28852", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-01-16"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "63158001.pdf", "filesize": [{"value": "1.4 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1400000.0, "url": {"label": "63158001.pdf", "url": "https://jaxa.repo.nii.ac.jp/record/5856/files/63158001.pdf"}, "version_id": "640e1b91-5abe-4492-8cd8-c77052155cac"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "撮像管", "subitem_subject_scheme": "Other"}, {"subitem_subject": "電子なだれ", "subitem_subject_scheme": "Other"}, {"subitem_subject": "HARP", "subitem_subject_scheme": "Other"}, {"subitem_subject": "アモルファス材料", "subitem_subject_scheme": "Other"}, {"subitem_subject": "量子効率", "subitem_subject_scheme": "Other"}, {"subitem_subject": "感度", "subitem_subject_scheme": "Other"}, {"subitem_subject": "光増幅器", "subitem_subject_scheme": "Other"}, {"subitem_subject": "光導電体", "subitem_subject_scheme": "Other"}, {"subitem_subject": "空間分解能", "subitem_subject_scheme": "Other"}, {"subitem_subject": "残像", "subitem_subject_scheme": "Other"}, {"subitem_subject": "画質", "subitem_subject_scheme": "Other"}, {"subitem_subject": "アモルファスセレン", "subitem_subject_scheme": "Other"}, {"subitem_subject": "a-Se", "subitem_subject_scheme": "Other"}, {"subitem_subject": "テレビカメラ", "subitem_subject_scheme": "Other"}, {"subitem_subject": "camera tube", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "electron avalanche", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "HARP", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "amorphous material", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "quantum efficiency", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "sensitivity", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "light amplifier", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "photoconductor", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "spatial resolution", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "afterimage", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "image quality", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "amorphous Se", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "a-Se", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "TV camera", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "超高感度HARP撮像管の研究開発とその応用", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "超高感度HARP撮像管の研究開発とその応用"}]}, "item_type_id": "5", "owner": "1", "path": ["1017", "1891"], "permalink_uri": "https://jaxa.repo.nii.ac.jp/records/5856", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-03-26"}, "publish_date": "2015-03-26", "publish_status": "0", "recid": "5856", "relation": {}, "relation_version_is_last": true, "title": ["超高感度HARP撮像管の研究開発とその応用"], "weko_shared_id": -1}
超高感度HARP撮像管の研究開発とその応用
https://jaxa.repo.nii.ac.jp/records/5856
https://jaxa.repo.nii.ac.jp/records/585645ceee5a-8f17-49be-bf33-af9ecf74f8ae
名前 / ファイル | ライセンス | アクション |
---|---|---|
63158001.pdf (1.4 MB)
|
|
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-03-26 | |||||
タイトル | ||||||
タイトル | 超高感度HARP撮像管の研究開発とその応用 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 撮像管 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 電子なだれ | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | HARP | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | アモルファス材料 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 量子効率 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 感度 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 光増幅器 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 光導電体 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 空間分解能 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 残像 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 画質 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | アモルファスセレン | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | a-Se | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | テレビカメラ | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | camera tube | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | electron avalanche | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | HARP | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | amorphous material | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | quantum efficiency | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | sensitivity | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | light amplifier | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | photoconductor | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | spatial resolution | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | afterimage | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | image quality | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | amorphous Se | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | a-Se | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | TV camera | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
その他のタイトル(英) | ||||||
その他のタイトル | Research and development of high sensitivity camera tube HARP and its application | |||||
著者 |
谷岡, 健吉
× 谷岡, 健吉× Tanioka, Kenkichi |
|||||
著者所属 | ||||||
日本放送協会 | ||||||
著者所属(英) | ||||||
en | ||||||
Japan Broadcasting Corporation | ||||||
出版者 | ||||||
出版者 | 宇宙航空研究開発機構 | |||||
出版者(英) | ||||||
出版者 | Japan Aerospace Exploration Agency (JAXA) | |||||
書誌情報 |
宇宙航空研究開発機構特別資料: 第2回学際領域における分子イメージングフォーラム en : JAXA Special Publication: Proceedings of the 2nd Interdisciplinary Forum on Molecular Imaging 巻 JAXA-SP-06-017, p. 2-13, 発行日 2006-11-16 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 撮像デバイスは、その感度が高ければ高いほど、暗い被写体でもより鮮明な映像として捉えることができる。このため、約80年の歴史を持つ撮像デバイスの研究においてもその高感度化は常に最重要テーマとして位置づけられてきた。当所でも1980年代の初頭に、超高感度と高画質の両立を可能とする新たな撮像デバイスの研究に着手した。その結果、1985年、光導電型撮像管のアモルファスセレン(a-Se)のターゲット(光電変換膜)を約10(exp 8)V/mの強電界で動作させた場合、アバランシェ増倍(電子なだれ増倍)現象が安定に連続して生じ、画質が良好な状態で極めて高い感度が得られることを見出した。これを基にHARP(High-gain Avalanche Rushing amorphous Photoconductor)とよばれる超高感度・高画質撮像管を開発、実用化した。HARP撮像管は、夜間緊急報道やオーロラ、夜行性動物の撮影などの放送用のみならず、深海探査研究やガンの早期発見などを目的としたX線医療診断の研究、新薬の開発などを目指した国のバイオ研究など、種々の分野の先端研究で活用されている。本稿では、HARP撮像管の発明の経緯と、今日までの長年の研究取り組みで高性能化が図られた超高感度HARP撮像管の特性を述べるとともに、この撮像技術によるさまざまな分野への応用を紹介する。 | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1349-113X | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA11984031 | |||||
資料番号 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 資料番号: AA0063158001 | |||||
レポート番号 | ||||||
内容記述タイプ | Other | |||||
内容記述 | レポート番号: JAXA-SP-06-017 |