{"created":"2023-06-20T14:46:22.190956+00:00","id":13912,"links":{},"metadata":{"_buckets":{"deposit":"c282d5dc-19a7-4cd1-bbf0-11c39d42f19f"},"_deposit":{"created_by":1,"id":"13912","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"13912"},"status":"published"},"_oai":{"id":"oai:jaxa.repo.nii.ac.jp:00013912","sets":["1543:1633:1648","1887:1891"]},"author_link":["127762","127761","127760","127763"],"item_5_alternative_title_2":{"attribute_name":"その他のタイトル(英)","attribute_value_mlt":[{"subitem_alternative_title":"Visual-otolithic mismatch suppresses the otolith-ocular reflex"}]},"item_5_biblio_info_10":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2003-02","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"15","bibliographicPageStart":"12","bibliographic_titles":[{"bibliographic_title":"宇宙利用シンポジウム 第19回 平成14年度"},{"bibliographic_title":"Space Utilization Research: Proceedings of the Nineteenth Space Utilization Symposium","bibliographic_titleLang":"en"}]}]},"item_5_description_17":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"When lateral linear acceleration (+/- 0.3 G, step-mode) was combined with optokinetic stimulation (40 deg/s), the slow-phase velocity of otolith-ocular reflex (OOR) was simply added to that of optokinetic response when both slow waves were in the 'same' direction, whereas OOR tended to be suppressed when they were in the 'opposite' direction (Space Util. Res. 18: 152-155, 2002). Such relation was well maintained with increase in acceleration from 0.3 to 0.5 G, supporting non-linearity in visual-vestibular interaction. It is known that such combined stimulation often induces motion sickness. Subjects often reported that discomfort was stronger in the 'opposite' phase than in the 'same' phase, suggesting that the motion sickness might be attributable to sensory conflict evoked by the 'opposite' situation and that OOR suppression might be an elementary process for its genesis. On analogy of this assumption, processes for generation and adaptation in space motion sickness were speculated.","subitem_description_type":"Other"}]},"item_5_description_32":{"attribute_name":"資料番号","attribute_value_mlt":[{"subitem_description":"資料番号: AA0045438005","subitem_description_type":"Other"}]},"item_5_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"宇宙科学研究所"}]},"item_5_publisher_9":{"attribute_name":"出版者(英)","attribute_value_mlt":[{"subitem_publisher":"The Institute of Space and Astronautical Science (ISAS)"}]},"item_5_text_6":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"名古屋大学環境医学研究所 宇宙医学実験センター"},{"subitem_text_value":"名古屋大学環境医学研究所 宇宙医学実験センター"}]},"item_5_text_7":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Research Institute of Environmental Medicine, Nagoya University Space Medicine Research Center"},{"subitem_text_language":"en","subitem_text_value":"Research Institute of Environmental Medicine, Nagoya University Space Medicine Research Center"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"森, 滋夫"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"片山, 直美"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Mori, Shigeo","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Katayama, Naomi","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"宇宙酔い","subitem_subject_scheme":"Other"},{"subitem_subject":"耳石器","subitem_subject_scheme":"Other"},{"subitem_subject":"感覚刺激","subitem_subject_scheme":"Other"},{"subitem_subject":"視覚刺激","subitem_subject_scheme":"Other"},{"subitem_subject":"微小重力","subitem_subject_scheme":"Other"},{"subitem_subject":"視動性応答","subitem_subject_scheme":"Other"},{"subitem_subject":"視覚と耳石器相互作用","subitem_subject_scheme":"Other"},{"subitem_subject":"線形加速","subitem_subject_scheme":"Other"},{"subitem_subject":"space motion sickness","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"otolith organ","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"sensory stimulation","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"visual stimulus","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"microgravity","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"optokinetic response","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"visual-otolithic interaction","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"linear acceleration","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"視覚と耳石器情報の不一致は耳石眼反射を抑制する","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"視覚と耳石器情報の不一致は耳石眼反射を抑制する"}]},"item_type_id":"5","owner":"1","path":["1648","1891"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-03-26"},"publish_date":"2015-03-26","publish_status":"0","recid":"13912","relation_version_is_last":true,"title":["視覚と耳石器情報の不一致は耳石眼反射を抑制する"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-06-21T05:42:48.996509+00:00"}