@techreport{oai:jaxa.repo.nii.ac.jp:00002710, author = {石澤, 淳一郎 and 馬場, 尚子 and Neish, Michael J. and 南, 伸太朗 and 今川, 吉郎 and 黒崎, 忠明 and 前島, 弘則 and 小島, 寧 and Ishizawa, Junichiro and Baba, Naoko and Neish, Michael J. and Minami, Shintaro and Imagawa, Kichiro and Kurosaki, Tadaaki and Maejima, Hironori and Kojima, Yasushi}, month = {Oct}, note = {ADEOS-2 (Advanced Earth Observing Satellite-2) stopped supplying observation data due to reduction of electric power supply. FTA (Fault Tree Analysis) suggested that breakage or short circuit of the power supply harness between PDL (Solar Array Paddle Subsystem) and the electric power subsystem was the most possible cause. Each phase of the failure scenario was evaluated with tests and analyses. This paper reports evaluation of material degradation for the failure case verification., 資料番号: AA0048057019, レポート番号: JAXA-RM-04-010}, title = {みどり2(ADEOS-2)運用異常に対する材料の劣化評価解析}, year = {2004} }