{"created":"2023-06-20T14:36:26.877089+00:00","id":2759,"links":{},"metadata":{"_buckets":{"deposit":"446c474d-13e3-48bd-9ffd-7e3e59e9432f"},"_deposit":{"created_by":1,"id":"2759","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"2759"},"status":"published"},"_oai":{"id":"oai:jaxa.repo.nii.ac.jp:00002759","sets":["1887:1893","9:1090:1333:1342"]},"author_link":["8829","8830"],"item_3_alternative_title_2":{"attribute_name":"その他のタイトル(英)","attribute_value_mlt":[{"subitem_alternative_title":"Test result: Effect of salting at cell terminals on cycle performance in Ni-Cd cell"}]},"item_3_biblio_info_10":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2004-03-25","bibliographicIssueDateType":"Issued"},"bibliographicVolumeNumber":"JAXA-RM-03-023","bibliographic_titles":[{"bibliographic_title":"宇宙航空研究開発機構研究開発資料"},{"bibliographic_title":"JAXA Research and Development Memorandum","bibliographic_titleLang":"en"}]}]},"item_3_description_16":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"1999年度に製作されたADEOS-2用FM50AhNi-Cd電池で発生したソルティング現象の、電池性能に与える影響を評価するために実施した、寿命評価試験結果をまとめた。放電深度25%、温度20度Cの周回軌道模擬サイクル1,000回において、放電末期電圧は1.19V以上、20度C容量は初期容量の97%以上あり、製品仕様書3.2.1.12(1)「作動寿命短期サイクル」要求の1.18V以上、85%以上を満足した。また、同一ロットの品質確認試験結果と有意な差はなく、ソルティング現象が電池性能に与える影響は無視しうるものと判断する。尚、試験は継続し、長期サイクルにおける寿命評価を行う。","subitem_description_type":"Abstract"}]},"item_3_description_32":{"attribute_name":"資料番号","attribute_value_mlt":[{"subitem_description":"資料番号: AA0046976000","subitem_description_type":"Other"}]},"item_3_description_33":{"attribute_name":"レポート番号","attribute_value_mlt":[{"subitem_description":"レポート番号: JAXA-RM-03-023","subitem_description_type":"Other"}]},"item_3_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"宇宙航空研究開発機構"}]},"item_3_publisher_9":{"attribute_name":"出版者(英)","attribute_value_mlt":[{"subitem_publisher":"Japan Aerospace Exploration Agency (JAXA)"}]},"item_3_source_id_21":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1349-1121","subitem_source_identifier_type":"ISSN"}]},"item_3_source_id_24":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA11983593","subitem_source_identifier_type":"NCID"}]},"item_3_text_6":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"宇宙航空研究開発機構 技術研究本部 搭載電源技術専門グループ"}]},"item_3_text_7":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Japan Aerospace Exploration Agency On-board Power Engineering Group, Office of Research and Development"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"艸分, 宏昌"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kusawake, Hiroaki","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-01-15"}],"displaytype":"detail","filename":"46976000.pdf","filesize":[{"value":"1.5 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"46976000.pdf","url":"https://jaxa.repo.nii.ac.jp/record/2759/files/46976000.pdf"},"version_id":"afe398e2-1f03-412f-836f-01eea5b6e8f1"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"ソルティング","subitem_subject_scheme":"Other"},{"subitem_subject":"ニッケルカドミウム電池","subitem_subject_scheme":"Other"},{"subitem_subject":"ADEOS-2","subitem_subject_scheme":"Other"},{"subitem_subject":"性能試験","subitem_subject_scheme":"Other"},{"subitem_subject":"放電","subitem_subject_scheme":"Other"},{"subitem_subject":"リーケージ","subitem_subject_scheme":"Other"},{"subitem_subject":"salting","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"nickel cadmium battery","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"ADEOS-2","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"performance test","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"electric discharge","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"leakage","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"technical report","resourceuri":"http://purl.org/coar/resource_type/c_18gh"}]},"item_title":"端子部ソルティングのNi-Cd電池のサイクル性能への影響:試験結果","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"端子部ソルティングのNi-Cd電池のサイクル性能への影響:試験結果"}]},"item_type_id":"3","owner":"1","path":["1342","1893"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-03-26"},"publish_date":"2015-03-26","publish_status":"0","recid":"2759","relation_version_is_last":true,"title":["端子部ソルティングのNi-Cd電池のサイクル性能への影響:試験結果"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-06-21T09:16:32.875380+00:00"}