{"created":"2023-06-20T15:02:15.752554+00:00","id":31349,"links":{},"metadata":{"_buckets":{"deposit":"7aa201e7-38b0-4e21-bd76-e6f16ef27200"},"_deposit":{"created_by":1,"id":"31349","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"31349"},"status":"published"},"_oai":{"id":"oai:jaxa.repo.nii.ac.jp:00031349","sets":["1887:1890","1896:1898:1899:1991"]},"author_link":["404067","404065","404066","404069","404068","404064"],"item_9_biblio_info_10":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1989-03","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"75","bibliographicPageStart":"65","bibliographicVolumeNumber":"9","bibliographic_titles":[{},{"bibliographic_title":"The Institute of Space and Astronautical Science report. S.P. : The Proceedings of the Symposium on Mechanics for Space Flight 1988","bibliographic_titleLang":"en"}]}]},"item_9_description_17":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"Thermosyphon works only on bottom heat mode and heat pipe equipped with wick can lift the returning working fluid about one meter at the best in gravitational field. If the thermosyphon has no directional restriction, it is very available and it can be used for wider purpose and area. A lot of suggestion has been proposed concerning top heat mode thermosyphons, however, a few report has been presented on the experimental research. The top heat mode thermosyphon equipped with liquid lifting pipe heated at its bottom is one influential solution for recirculation of the working fluid.","subitem_description_type":"Other"}]},"item_9_description_32":{"attribute_name":"資料番号","attribute_value_mlt":[{"subitem_description":"資料番号: SA0033630000","subitem_description_type":"Other"}]},"item_9_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"宇宙科学研究所"}]},"item_9_publisher_9":{"attribute_name":"出版者(英)","attribute_value_mlt":[{"subitem_publisher":"Institute of Space and Astronautical Science"}]},"item_9_source_id_21":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0288-433X","subitem_source_identifier_type":"ISSN"}]},"item_9_source_id_24":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA10455137","subitem_source_identifier_type":"NCID"}]},"item_9_text_7":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Takuma Research and Development Co., Ltd"},{"subitem_text_language":"en","subitem_text_value":"Takuma Research and Development Co., Ltd"},{"subitem_text_language":"en","subitem_text_value":"Takuma Research and Development Co., Ltd"},{"subitem_text_language":"en","subitem_text_value":"Tokyo Metropolitan Institute of Technology"},{"subitem_text_language":"en","subitem_text_value":"University of Osaka"},{"subitem_text_language":"en","subitem_text_value":"University of Osaka"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"HIRASHIMA, M.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"NISHIKAWA, Y.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"TAGUCHI, M.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"NEGISHI, K.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"KANEKO, K.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"TAKEMURA, M.","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-01-23"}],"displaytype":"detail","filename":"SA0033630.pdf","filesize":[{"value":"515.1 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"SA0033630.pdf","url":"https://jaxa.repo.nii.ac.jp/record/31349/files/SA0033630.pdf"},"version_id":"4e4a4297-a819-4431-ba49-17d2803100f8"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Characterstics of Top Heat Mode Thermosyphons (Part II : An Improved Model)","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Characterstics of Top Heat Mode Thermosyphons (Part II : An Improved Model)","subitem_title_language":"en"}]},"item_type_id":"9","owner":"1","path":["1890","1991"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-03-26"},"publish_date":"2015-03-26","publish_status":"0","recid":"31349","relation_version_is_last":true,"title":["Characterstics of Top Heat Mode Thermosyphons (Part II : An Improved Model)"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-06-21T01:02:31.042820+00:00"}