{"created":"2023-06-20T15:02:19.480239+00:00","id":31416,"links":{},"metadata":{"_buckets":{"deposit":"42981c04-84b0-4f81-b47f-701dac0d55b8"},"_deposit":{"created_by":1,"id":"31416","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"31416"},"status":"published"},"_oai":{"id":"oai:jaxa.repo.nii.ac.jp:00031416","sets":["1887:1890","1896:1898:1899:1903"]},"author_link":["404246","404245","404247"],"item_9_biblio_info_10":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1992-10","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"9","bibliographicPageStart":"1","bibliographicVolumeNumber":"649","bibliographic_titles":[{},{"bibliographic_title":"The Institute of Space and Astronautical Science report","bibliographic_titleLang":"en"}]}]},"item_9_description_17":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"The noise due to laser frequency fluctuation in a Michelson interferometer can be suppressed by making the arm length difference equal to zero. But it is difficult to match the arm lengths in the interferometers with a large number of reflections in delay-lines. In this paper we show result that it is possible to achieve CMRR (Common Mode Rejection Ratio) of 119dB for the noise due to laser frequency fluctuation, by using the mirrors with small relative difference to radii of curvature and most tiltless surfaces.","subitem_description_type":"Other"}]},"item_9_description_32":{"attribute_name":"資料番号","attribute_value_mlt":[{"subitem_description":"資料番号: SA0035158000","subitem_description_type":"Other"}]},"item_9_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"宇宙科学研究所"}]},"item_9_publisher_9":{"attribute_name":"出版者(英)","attribute_value_mlt":[{"subitem_publisher":"Institute of Space and Astronautical Science"}]},"item_9_source_id_21":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0285-6808","subitem_source_identifier_type":"ISSN"}]},"item_9_source_id_24":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA10632072","subitem_source_identifier_type":"NCID"}]},"item_9_text_7":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Bubble Chamber Physics Laboratory, Tohoku University"},{"subitem_text_language":"en","subitem_text_value":"The Institute of Space and Astronautical Science"},{"subitem_text_language":"en","subitem_text_value":"The Institute of Space and Astronautical Science"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"TAKAHASHI, R.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"MIZUNO, J.","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"KAWASHIMA, N.","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-01-23"}],"displaytype":"detail","filename":"SA0035158.pdf","filesize":[{"value":"481.2 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"SA0035158.pdf","url":"https://jaxa.repo.nii.ac.jp/record/31416/files/SA0035158.pdf"},"version_id":"6b5efa2b-ec73-461c-8c79-11a9199bb0ff"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Arm Length Matching in 10m Delay-Line Interferometer","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Arm Length Matching in 10m Delay-Line Interferometer","subitem_title_language":"en"}]},"item_type_id":"9","owner":"1","path":["1890","1903"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-03-26"},"publish_date":"2015-03-26","publish_status":"0","recid":"31416","relation_version_is_last":true,"title":["Arm Length Matching in 10m Delay-Line Interferometer"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-06-21T01:00:25.290089+00:00"}