@article{oai:jaxa.repo.nii.ac.jp:00032810, author = {近藤, 豊 and 高木, 増美 and 岩田, 晃 and KONDO, Yutaka and TAKAGI, Masumi and IWATA, Akira}, journal = {宇宙科学研究所報告. 特集: 大気球研究報告}, month = {Aug}, note = {大気球をplatformとしたSolar occultation法により, Chappuis帯の吸収を利用して成層圏オゾンの密度を15-25kmの領域で測定した。同時に測定されたオゾンゾンデの測定値と比べた時, ゾンデの測定誤差や両者の測定法の差異を考えた場合, 良好な一致が見られた。, Stratospheric ozone in the altitude region of 15-25km has been measured by balloon borne filter sun-photometers. Concentrations of ozone deduced from the absorption in Chappuis band are in good agreement with those obtained by ozone sondes on board the same balloons. Possible causes of the differences of the profiles obtained by the two methods are discussed., 資料番号: SA0166571000}, pages = {87--91}, title = {Chappuis 帯の吸収を利用した成層圏オゾンの測定}, volume = {4}, year = {1982} }