{"created":"2023-06-20T15:03:37.247821+00:00","id":32837,"links":{},"metadata":{"_buckets":{"deposit":"e30c56a3-3baf-467e-8aac-5c818885fa2d"},"_deposit":{"created_by":1,"id":"32837","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"32837"},"status":"published"},"_oai":{"id":"oai:jaxa.repo.nii.ac.jp:00032837","sets":["1887:1890","1896:1898:1899:1912"]},"author_link":["412024","412026","412029","412023","412025","412027","412032","412022","412033","412031","412028","412030"],"item_9_alternative_title_2":{"attribute_name":"その他のタイトル(英)","attribute_value_mlt":[{"subitem_alternative_title":"Cryogenic Temperature Measurement in the Development of LH_2/LOX Engine"}]},"item_9_biblio_info_10":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1983-03","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"352","bibliographicPageStart":"329","bibliographicVolumeNumber":"6","bibliographic_titles":[{"bibliographic_title":"宇宙科学研究所報告. 特集: 液水/液酸エンジンの開発研究報告"}]}]},"item_9_description_16":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"1976年にはじまった宇宙科学研究所のLH_2/LOXエンジン開発における温度計測, とくに低温および極低温の計測についての経過, 得られた知見を述べ, あわせて問題点を論じる。13.81Kまでの国際実用温度目盛を確立したIPTS-68に準拠した測定値を得るために, 最も重要な一次変換器として熱電対にはクロメル/金-0.07at%鉄(KP/AuFe)を, 測温抵抗体には白金-0.5mol%コバルト (PCoRT) を選び, トレーサブルな計測を目指して極低温温度校正装置を用い, できるだけ実際の計測に即した校正を行なった。測定系の精度を左右する多くの因子, 例えばセンサ差込長, 補償導線の接続法や基準接点の構造が適正であるか, 増幅器の安定性, 定電圧・定電流発生器の精度, 収録機器の性能が満足すべきものであるかどうか, などについて実験毎に検討を重ね, ようやく要求精度0.5Kに応えられる計測システムの確立をみた。","subitem_description_type":"Abstract"}]},"item_9_description_17":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"In the present paper are described the processes, barrier problems and know-how on temperature measurement, particularly at low and cryogenic temperatures which have played an important role in developmental experiments of an LH_2/LOX rocket engine since 1976. In order to make reproducible and reliable temperature measurements based on IPTS-68 firmly established down to 13.81K and acquire some correct calibration curves, using Chromel vs Au-0.07at%Fe (KP/AuFe) thermocouples, and Pt-0.5 mol%Co(PCoRT) resistance bulbs as a first transducer, we have operated 'in-place' calibration for traceable temperature measurement by a cryogenic temperature calibrator. Various factors affording influences on the accuracy of measurement have been investigated, e.g., the suitability of inserted length for sensor, connecting method of compensating lead wires, the structure of fixed points, the stability of amplifiers, the properties of recording instruments, at every experiment. Lately we have succeeded in establishing the measurement system with the allowance less than 0.5K.","subitem_description_type":"Other"}]},"item_9_description_32":{"attribute_name":"資料番号","attribute_value_mlt":[{"subitem_description":"資料番号: SA0166606000","subitem_description_type":"Other"}]},"item_9_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"宇宙科学研究所"}]},"item_9_publisher_9":{"attribute_name":"出版者(英)","attribute_value_mlt":[{"subitem_publisher":"Institute of Space and Astronautical Science"}]},"item_9_source_id_21":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0285-9920","subitem_source_identifier_type":"ISSN"}]},"item_9_source_id_24":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00354485","subitem_source_identifier_type":"NCID"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"青柳, 鐘一郎"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"霜田, 正隆"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"加勇田, 清勇"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"斉藤, 猛男"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"山谷, 寿夫"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"岩間, 彬"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"AOYAGI, Shoichiro","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"SHIMODA, Masataka","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"KAYUTA, Seiyu","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"SAITO, Takeo","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"YAMAYA, Toshio","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"IWAMA, Akira","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-01-24"}],"displaytype":"detail","filename":"SA0166606.pdf","filesize":[{"value":"1.6 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"SA0166606.pdf","url":"https://jaxa.repo.nii.ac.jp/record/32837/files/SA0166606.pdf"},"version_id":"37118f67-b156-4f93-9746-766946954f9d"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"LH_2/LOX エンジン開発における極低温温度計測","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"LH_2/LOX エンジン開発における極低温温度計測"}]},"item_type_id":"9","owner":"1","path":["1890","1912"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-03-26"},"publish_date":"2015-03-26","publish_status":"0","recid":"32837","relation_version_is_last":true,"title":["LH_2/LOX エンジン開発における極低温温度計測"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-06-21T00:22:45.090335+00:00"}