@article{oai:jaxa.repo.nii.ac.jp:00032864, author = {小川, 徹 and 北野, 正雄 and 藪崎, 努 and OGAWA, Toru and KITANO, Masao and YABUZAKI, Tsutomu}, journal = {宇宙科学研究所報告. 特集: 宇宙観測研究報告}, month = {Mar}, note = {Optically pumped magnetometer with single spectral line is proposed as a space magnetometer and a station geomagnetic standard. The results obtained can be summarized as follows. (1) ^<39>K is most suitable for this purpose due to the separation of Zeeman sub-levels and its high natural abundance. (2) Errors due to spectral asymmetry is very small. (3) Errors due to the nearest neighbor line can be made very small. (4) Stability in the short time and the long time intervals will become to the order of 10^<-2>nT and 10^<-1>nT, respectively. The light sources of optical pumping are also discussed., 資料番号: SA0166648000}, pages = {73--81}, title = {単一スペクトル線光ポンピング磁力計}, volume = {9}, year = {1984} }