{"created":"2023-06-20T15:04:07.044982+00:00","id":33332,"links":{},"metadata":{"_buckets":{"deposit":"f395b63f-2dc7-4ecc-b62d-1d718e56d689"},"_deposit":{"created_by":1,"id":"33332","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"33332"},"status":"published"},"_oai":{"id":"oai:jaxa.repo.nii.ac.jp:00033332","sets":["1887:1890","1896:1898:1899:1912"]},"author_link":["416689","416690","416693","416692","416697","416698","416696","416695","416694","416691"],"item_9_biblio_info_10":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2003-03","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"36","bibliographicPageStart":"31","bibliographicVolumeNumber":"45","bibliographic_titles":[{"bibliographic_title":"宇宙科学研究所報告. 特集: 大気球研究報告"}]}]},"item_9_description_17":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"This article describes a network of high voltage power supplies which are controlled and managed through a network. The high voltage power supply incorporates a ceramic transformer which utilizes piezoelectric effect to generate high voltage. The ceramic transformer is constructed from a ceramic bar and does not include any magnetic material. A high voltage power supply can work without a loss of efficiency under a magnetic field of 1.5 tesla. The power supply includes feedback to stabilize the high voltage output, supplying from 2000V to 4000V with a load of more than 10MΩ at efficiency higher than 60 percent. The high voltage power supply includes a Neuron chip, a programming device processing a variety of input and output capabilities. The chip can also communicate with other Neuron chips over a twisted-pair cable, which allows establishing a high voltage control network consisting of a number of power supplies that incorporate the chip individually. The functions of the power supply under the control of the chip are managed through the network. The chip turns on and off the high voltage power supply and sets the output high voltage. The chip detects the short circuit of the output high voltage and controls its recovery. The chip also monitors the output current. Thus the high voltage power supplies are monitored and controlled through the network.","subitem_description_type":"Other"}]},"item_9_description_32":{"attribute_name":"資料番号","attribute_value_mlt":[{"subitem_description":"資料番号: SA0200105000","subitem_description_type":"Other"}]},"item_9_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"宇宙科学研究所"}]},"item_9_publisher_9":{"attribute_name":"出版者(英)","attribute_value_mlt":[{"subitem_publisher":"Institute of Space and Astronautical Science"}]},"item_9_source_id_21":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0285-9920","subitem_source_identifier_type":"ISSN"}]},"item_9_source_id_24":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00354485","subitem_source_identifier_type":"NCID"}]},"item_9_text_6":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"東京大学"},{"subitem_text_value":"東京大学"},{"subitem_text_value":"神戸大学"},{"subitem_text_value":"東京大学"},{"subitem_text_value":"高エネルギー加速器研究機構"}]},"item_9_text_7":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"International Center for Elementary Particle Physics, University of Tokyo"},{"subitem_text_language":"en","subitem_text_value":"International Center for Elementary Particle Physics, University of Tokyo"},{"subitem_text_language":"en","subitem_text_value":"Faculty of Science, Kobe University"},{"subitem_text_language":"en","subitem_text_value":"Faculty of Science, Department of Physics, University of Tokyo"},{"subitem_text_language":"en","subitem_text_value":"National Laboratory for High Energy Physics (KEK)"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"松本, 浩"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"井森, 正敏"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"志風, 義明"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"福家, 英之"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"谷口, 敬"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Matsumoto, Hiroshi","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Imori, Masatosi","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Shikaze, Yoshiaki","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Fuke, Hideyuki","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Taniguchi, Takashi","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-01-24"}],"displaytype":"detail","filename":"SA0200105.pdf","filesize":[{"value":"416.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"SA0200105.pdf","url":"https://jaxa.repo.nii.ac.jp/record/33332/files/SA0200105.pdf"},"version_id":"993f515d-bedf-4bef-9d00-9e846e37c7b1"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Network-Controlled High Voltage Power Supply Working in Magnetic Field","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Network-Controlled High Voltage Power Supply Working in Magnetic Field","subitem_title_language":"en"}]},"item_type_id":"9","owner":"1","path":["1890","1912"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-03-26"},"publish_date":"2015-03-26","publish_status":"0","recid":"33332","relation_version_is_last":true,"title":["Network-Controlled High Voltage Power Supply Working in Magnetic Field"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-06-21T00:09:54.744880+00:00"}