@article{oai:jaxa.repo.nii.ac.jp:00033810, author = {熊谷, 寛夫 and 山田, 和郎 and 岩永, 賢三 and Kumagai, Hiroo and Yamada, Kazuo and Iwanaga, Kenzo}, issue = {9/10}, journal = {東京大學理工學研究所報告}, month = {Jan}, note = {The reflex klytron has found wide applications as local oscillators and power sources for microwave spectroscopy in pure physics. We designed a demountable, klystron tube of the single-gap reflex type in order to examine the character of the tube itself. We used the oxide coated cathode in stead of the tungsten cathode and found that it had sufficient emissivity of electron and also had long. life of several ten hours at the pressure evacuated by the two-stage oil diffusion pump designed in our laboratory. The wave length of the oscillator was 5cm and the minimum starting current was 1.5mA. The power output is sufficient for physical experiments in laboratories., 資料番号: SA0701302000}, pages = {249--253}, title = {反射型速度變調管の試作について(物理學)}, volume = {3}, year = {1950} }