{"created":"2023-06-20T15:05:23.683700+00:00","id":34693,"links":{},"metadata":{"_buckets":{"deposit":"cba1e627-ca5b-4104-b389-93d785cbe032"},"_deposit":{"created_by":1,"id":"34693","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"34693"},"status":"published"},"_oai":{"id":"oai:jaxa.repo.nii.ac.jp:00034693","sets":["1887:1890","1896:1898:1899:1908"]},"author_link":["420230","420228","420231","420229"],"item_9_alternative_title_2":{"attribute_name":"その他のタイトル(英)","attribute_value_mlt":[{"subitem_alternative_title":"On a Correction of the Dilution Ratio as a Relative Measure of Solvent Power for a Polymer"}]},"item_9_biblio_info_10":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1954-03-08","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"6","bibliographicPageEnd":"236","bibliographicPageStart":"229","bibliographicVolumeNumber":"7","bibliographic_titles":[{"bibliographic_title":"東京大學理工學研究所報告"}]}]},"item_9_description_17":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"Although the dilution ratio-that indicates the volume fraction of non-solvent in the total solution at the precipitation point, to which a polymer Solution of a standard concentration is brought by the addition of non-solvent-has been believed to be applicable as a relative measure of the solvent power of the solvent used, there exists much experimental evidence against it. The reason why the dilution ratio cannot be, for a polymer, a relative measure of evaluating solvent power has been explained from Huggins-Flory's theory of the solubility of polymer, and a method of correcting the measured dilution ratio for the aim of making it applicable as a measure of solvent power has been proposed. Experimental results on nitrocellulose and polybutene have shown that, in each case of these polymers, the greater the dilution ratio corrected by that method, the higher the value of [η]/V^2 is, where [η] is the intrinsic viscosity, V in the molar volume of solvent and further that the relation between them can almost practically be represented by a smooth curve. For a given polymer, the corrected dilution ratio can, therefore, be accepted as a relative measure of solvent power, since [η]/V^2 is, as shown in the previous paper, applicable as such a measure.","subitem_description_type":"Other"}]},"item_9_description_32":{"attribute_name":"資料番号","attribute_value_mlt":[{"subitem_description":"資料番号: SA2410175000","subitem_description_type":"Other"}]},"item_9_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"東京大学理工学研究所"}]},"item_9_source_id_21":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0371-6090","subitem_source_identifier_type":"ISSN"}]},"item_9_source_id_24":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00162611","subitem_source_identifier_type":"NCID"}]},"item_9_text_6":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"東京大学理工学研究所"},{"subitem_text_value":"東京大学理工学研究所"}]},"item_9_text_7":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"THE INSTITUTE OF SCIENCE AND TECHNOLOGY, UNIVERSITY OF TOKYO"},{"subitem_text_language":"en","subitem_text_value":"THE INSTITUTE OF SCIENCE AND TECHNOLOGY, UNIVERSITY OF TOKYO"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"山口, 文之助"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"大木, 喬"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"YAMAGUCHI, BUNNOSUKE","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"OKI, TAKASHI","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-01-24"}],"displaytype":"detail","filename":"SA2410175.pdf","filesize":[{"value":"764.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"SA2410175.pdf","url":"https://jaxa.repo.nii.ac.jp/record/34693/files/SA2410175.pdf"},"version_id":"78fdcca2-dbab-4888-9744-eaabf0e9a7a0"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"高分子溶液における溶媒力の尺度としての沈澱剤率の補正について","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"高分子溶液における溶媒力の尺度としての沈澱剤率の補正について"}]},"item_type_id":"9","owner":"1","path":["1890","1908"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-03-26"},"publish_date":"2015-03-26","publish_status":"0","recid":"34693","relation_version_is_last":true,"title":["高分子溶液における溶媒力の尺度としての沈澱剤率の補正について"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-06-20T23:36:38.588647+00:00"}