{"created":"2023-06-20T15:07:59.879031+00:00","id":37382,"links":{},"metadata":{"_buckets":{"deposit":"3b572e73-acd8-4307-b63b-d890ac3a902a"},"_deposit":{"created_by":1,"id":"37382","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"37382"},"status":"published"},"_oai":{"id":"oai:jaxa.repo.nii.ac.jp:00037382","sets":["1887:1891","1896:1898:1913:1915"]},"author_link":["480452","480453","480457","480454","480456","480455"],"item_5_alternative_title_2":{"attribute_name":"その他のタイトル(英)","attribute_value_mlt":[{"subitem_alternative_title":"MSBS research at NAL"}]},"item_5_biblio_info_10":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1999-05","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"23","bibliographicPageStart":"9","bibliographicVolumeNumber":"42","bibliographic_titles":[{"bibliographic_title":"航空宇宙技術研究所特別資料"},{"bibliographic_title":"Special Publication of National Aerospace Laboratory","bibliographic_titleLang":"en"}]}]},"item_5_description_14":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"21-22 May 1998 (60th). 26-27 Nov. 1998 (61st)","subitem_description_type":"Other"}]},"item_5_description_15":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)(英)","attribute_value_mlt":[{"subitem_description":"21-22 May 1998 (60th). 26-27 Nov. 1998 (61st)","subitem_description_type":"Other"}]},"item_5_description_16":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"航技研では、1986年に10cm角測定部の低速風洞用磁力支持天秤装置の研究を開始して以来、1987年に我が国初の磁力支持に成功し、1993年には世界最大の測定部を持つ60cm磁力支持天秤装置による模型支持に成功した。また、模型位置姿勢測定装置の開発、模型運動の6自由度総てを磁力制御する試みや、ホール素子を用い磁場強さを測定し、模型に加わる慣性力を利用した動的な天秤較正試験などを行った。現在は、模型内部に組み込んだ模型姿勢制御法の研究、模型用磁石コアの代わりに超電導コイルを用いる試験を進めている。","subitem_description_type":"Abstract"}]},"item_5_description_17":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"National Aerospace Laboratory (NAL) started the research on Magnetic Suspension and Balance System (MSBS) in 1986 for the low speed wind tunnel with 10 cm square test section, and was successful in the first magnetic force suspension in Japan in 1987, and in the model suspension in 1993 by the 60 cm MSBS with the world largest test section. Further, there have been researches done such as the development of the model position attitude measurement apparatus, the trial for magnetic control of all six degrees of freedom of the model motion, the measurement of the magnetic filed strength with a Hall device, and the dynamic balance calibration test utilizing the inertial force added to the model. Now, the research on the model attitude control method constructed within the model and the test with superconducting coil instead of magnet cores for models are in progress.","subitem_description_type":"Other"}]},"item_5_description_32":{"attribute_name":"資料番号","attribute_value_mlt":[{"subitem_description":"資料番号: AA0001959002","subitem_description_type":"Other"}]},"item_5_description_33":{"attribute_name":"レポート番号","attribute_value_mlt":[{"subitem_description":"レポート番号: NAL SP-42","subitem_description_type":"Other"}]},"item_5_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"航空宇宙技術研究所"}]},"item_5_publisher_9":{"attribute_name":"出版者(英)","attribute_value_mlt":[{"subitem_publisher":"National Aerospace Laboratory (NAL)"}]},"item_5_source_id_21":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0289-260X","subitem_source_identifier_type":"ISSN"}]},"item_5_source_id_24":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN10097345","subitem_source_identifier_type":"NCID"}]},"item_5_text_6":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"航空宇宙技術研究所"},{"subitem_text_value":"航空宇宙技術研究所"},{"subitem_text_value":"航空宇宙技術研究所"}]},"item_5_text_7":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"National Aerospace Laboratory"},{"subitem_text_language":"en","subitem_text_value":"National Aerospace Laboratory"},{"subitem_text_language":"en","subitem_text_value":"National Aerospace Laboratory"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"澤田, 秀夫"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"河野, 敬"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"国益, 徹也"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Sawada, Hideo","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kono, Takashi","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kunimasu, Tetsuya","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-02-10"}],"displaytype":"detail","filename":"nalsp0042002.pdf","filesize":[{"value":"2.2 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"nalsp0042002.pdf","url":"https://jaxa.repo.nii.ac.jp/record/37382/files/nalsp0042002.pdf"},"version_id":"787ce8cb-e77a-48b2-9006-49ca9bd448e7"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"磁力支持天秤装置","subitem_subject_scheme":"Other"},{"subitem_subject":"MSBS","subitem_subject_scheme":"Other"},{"subitem_subject":"模型位置姿勢測定装置","subitem_subject_scheme":"Other"},{"subitem_subject":"磁力制御","subitem_subject_scheme":"Other"},{"subitem_subject":"ホール素子","subitem_subject_scheme":"Other"},{"subitem_subject":"動的天秤較正","subitem_subject_scheme":"Other"},{"subitem_subject":"模型姿勢制御","subitem_subject_scheme":"Other"},{"subitem_subject":"超電導コイル","subitem_subject_scheme":"Other"},{"subitem_subject":"magnetic suspension and balance system","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"MSBS","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"model position attitude measurement apparatus","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"magnetic control","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Hall device","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"dynamic balance calibration","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"model attitude control","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"superconductive coil","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"航技研における磁力支持天秤装置の研究","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"航技研における磁力支持天秤装置の研究"}]},"item_type_id":"5","owner":"1","path":["1891","1915"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-03-26"},"publish_date":"2015-03-26","publish_status":"0","recid":"37382","relation_version_is_last":true,"title":["航技研における磁力支持天秤装置の研究"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-06-20T21:20:21.332453+00:00"}