Item type |
会議発表論文 / Conference Paper(1) |
公開日 |
2016-02-04 |
タイトル |
|
|
タイトル |
Comparison between Measured and Simulated Radiation Doses in the Matoroshka-R Spherical phantom Experiment#1 and Area Monitoring aboard International Space Station using PADLES from May - Sep. 2012 |
|
言語 |
en |
言語 |
|
|
言語 |
eng |
資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_5794 |
|
資源タイプ |
conference paper |
アクセス権 |
|
|
アクセス権 |
metadata only access |
|
アクセス権URI |
http://purl.org/coar/access_right/c_14cb |
著者 |
Nagamatsu, Aiko
Tolochek, Raisa
Shurshakov, Vyacheslav
Nikolaev, Igor
Tawara, Hiroko
Kitajo, Keiichi
Shimada, Ken
|
著者所属(英) |
|
|
|
en |
|
|
Japan Aerospace Exploration Agency(JAXA) |
著者所属(英) |
|
|
|
en |
|
|
- |
著者所属(英) |
|
|
|
en |
|
|
- |
著者所属(英) |
|
|
|
en |
|
|
- |
著者所属(英) |
|
|
|
en |
|
|
- |
著者所属(英) |
|
|
|
en |
|
|
- |
著者所属(英) |
|
|
|
en |
|
|
- |
出版者(英) |
|
|
出版者 |
COSPAR |
書誌情報 |
en : 40th COSPAR Scientific Assembly
発行日 2014-08
|
会議概要(会議名, 開催地, 会期, 主催者等)(英) |
|
|
内容記述タイプ |
Other |
|
内容記述 |
40th COSPAR Scientific Assembly (August 2-10, 2014.), Moscow, Russia |
抄録(英) |
|
|
内容記述タイプ |
Other |
|
内容記述 |
The measurement of radiation environmental parameters in space is essential to support radiation risk assessments for astronauts and establish a benchmark for space radiation models for present and future human space activities. Since Japanese Experiment Module `KIBO' was attached to the International Space Station (ISS) in 2008, we have been performing continuous space radiation dosimetery using a PADLES (Passive Dosimeter for Life-Science Experiments in Space) consisting of CR-39 PNTDs (Plastic Nuclear track detectors) and TLD-MSOs (Mg2SiO4:Tb) for various space experiments onboard the `KIBO' part of the ISS. The MATROSHKA-R experiments aims to verify of dose distributions in a human body during space flight. The phantom consists of tissue equivalent material covered by a poncho jacket with 32 pockets on the surface. 20 container rods with dosimeters can be struck into the spherical phantom. Its diameter is 370 mm and it is 32 kg in weight. The first experiment onboard the KIBO at Forward No.2 area (JPM1F2 Rack2) was conducted over 114 days from 21 May to 12 September 2012 (the installation schedule inside the phantom) on the way to solar cycle 24th upward curve. 16 PADLES packages were deployed into 16 poncho pockets on the surface of the spherical phantom. Another 12 PADLES packages were deployed inside 4 rods (3 packages per rod in the outer, middle and inner side). Area monitoring in the KIBO was conducted in the same period (Area PADLES series #8 from 15 May to 16 September, 2012). Absorbed doses were measured at 17 area monitoring points in the KIBO and 28 locations (16 packages in poncho pockets and 12 inside 4 rods) in the phantom. The maximum value measured with the PADLES in the poncho pockets on the surface of the spherical phantom facing the outer wall was 0.43 mGy/day and the minimum value measured with the PADLES in the poncho pockets on the surface of the spherical phantom facing the KIBO interior was 0.30 mGy/day. The maximum absorbed doses measured inside rods was 0.28 mGy/day and the minimum value was 0.19 mGy/day. This indicates doses measured from the dosimeters placed in the outer side of each rod are relatively high compared to the doses placed in the center of rod. At this time, we also would like to show the preliminary results of comparative study between measured and Simulated Radiation Doses using the Particle and Heavy Ion Transport code System (PHITS) calculations with well developed shielding model of the KIBO and numerical spherical phantom inside. |
資料番号 |
|
|
内容記述タイプ |
Other |
|
内容記述 |
資料番号: AC1500109000 |