{"created":"2023-06-20T15:10:22.225479+00:00","id":39952,"links":{},"metadata":{"_buckets":{"deposit":"130c35e6-7f1e-4c5e-ab58-107c827d96c9"},"_deposit":{"created_by":1,"id":"39952","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"39952"},"status":"published"},"_oai":{"id":"oai:jaxa.repo.nii.ac.jp:00039952","sets":["1887:1893","1896:1898:1913:1916"]},"author_link":["445732","445735","445730","445729","445733","445728","445734","445731"],"item_3_alternative_title_2":{"attribute_name":"その他のタイトル(英)","attribute_value_mlt":[{"subitem_alternative_title":"Technical problems and solutions in replacement of wind tunnel facilities"}]},"item_3_biblio_info_10":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1997-06","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"19","bibliographicPageStart":"1","bibliographicVolumeNumber":"713","bibliographic_titles":[{"bibliographic_title":"航空宇宙技術研究所資料"},{"bibliographic_title":"Technical Memorandum of National Aerospace Laboratory","bibliographic_titleLang":"en"}]}]},"item_3_description_16":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"1985年の計画から始まった大規模な風洞用設備(遷音速風洞および吹出式風洞に供する設備)の更新は、1995年に終了した。風洞用設備の計画時および更新工事時に既設設備との適合性および設備運用の観点から、調査、検討を行った技術課題や留意事項、ならびに更新工事における解決の実際について報告する。","subitem_description_type":"Abstract"}]},"item_3_description_17":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"Seven devices related to the NAL wind tunnel facilities were replaced in succession from 1985 to 1995. This paper describes some considerations on the function of each device, the technical problems that occurred, and precautions to be taken in the replacement of wind tunnel facilities.","subitem_description_type":"Other"}]},"item_3_description_32":{"attribute_name":"資料番号","attribute_value_mlt":[{"subitem_description":"資料番号: AA0001068000","subitem_description_type":"Other"}]},"item_3_description_33":{"attribute_name":"レポート番号","attribute_value_mlt":[{"subitem_description":"レポート番号: NAL TM-713","subitem_description_type":"Other"}]},"item_3_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"航空宇宙技術研究所"}]},"item_3_publisher_9":{"attribute_name":"出版者(英)","attribute_value_mlt":[{"subitem_publisher":"National Aerospace Laboratory (NAL)"}]},"item_3_source_id_21":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0452-2982","subitem_source_identifier_type":"ISSN"}]},"item_3_source_id_24":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00314334","subitem_source_identifier_type":"NCID"}]},"item_3_text_6":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"航空宇宙技術研究所 空力性能部"},{"subitem_text_value":"航空宇宙技術研究所 空力性能部"},{"subitem_text_value":"航空宇宙技術研究所 空力性能部"},{"subitem_text_value":"航空宇宙技術研究所 空力性能部"}]},"item_3_text_7":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"National Aerospace Laboratory Aircraft Aerodynamics Division"},{"subitem_text_language":"en","subitem_text_value":"National Aerospace Laboratory Aircraft Aerodynamics Division"},{"subitem_text_language":"en","subitem_text_value":"National Aerospace Laboratory Aircraft Aerodynamics Division"},{"subitem_text_language":"en","subitem_text_value":"National Aerospace Laboratory Aircraft Aerodynamics Division"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"小松, 行夫"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"鈴木, 正光"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"唐沢, 敏夫"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"末永, 尚史"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Komatsu, Yukio","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Suzuki, Masamitsu","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Karasawa, Toshio","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Suenaga, Hisashi","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-01-27"}],"displaytype":"detail","filename":"naltm0000713.pdf","filesize":[{"value":"473.8 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"naltm0000713.pdf","url":"https://jaxa.repo.nii.ac.jp/record/39952/files/naltm0000713.pdf"},"version_id":"e8ff661b-339d-4a7d-92a9-1b9f9894b29a"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"遷音速風洞","subitem_subject_scheme":"Other"},{"subitem_subject":"吹出風洞","subitem_subject_scheme":"Other"},{"subitem_subject":"風洞設備","subitem_subject_scheme":"Other"},{"subitem_subject":"風洞設備計画","subitem_subject_scheme":"Other"},{"subitem_subject":"風洞工事計画","subitem_subject_scheme":"Other"},{"subitem_subject":"空気圧縮機","subitem_subject_scheme":"Other"},{"subitem_subject":"排風機","subitem_subject_scheme":"Other"},{"subitem_subject":"吸込管","subitem_subject_scheme":"Other"},{"subitem_subject":"冷却器","subitem_subject_scheme":"Other"},{"subitem_subject":"電動機","subitem_subject_scheme":"Other"},{"subitem_subject":"マンマシーンインターフェース","subitem_subject_scheme":"Other"},{"subitem_subject":"transonic wind tunnel","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"blowdown wind tunnel","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"wind tunnel facility","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"wind tunnel facility plan","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"wind tunnel facility construction","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"air compressor","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"exhaust fan","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"suction pipe","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"cooler","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"electric motor","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"man machine interface","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"technical report","resourceuri":"http://purl.org/coar/resource_type/c_18gh"}]},"item_title":"風洞設備更新における技術課題と工事","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"風洞設備更新における技術課題と工事"}]},"item_type_id":"3","owner":"1","path":["1893","1916"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-03-26"},"publish_date":"2015-03-26","publish_status":"0","recid":"39952","relation_version_is_last":true,"title":["風洞設備更新における技術課題と工事"],"weko_creator_id":"1","weko_shared_id":1},"updated":"2023-06-20T19:18:05.548185+00:00"}