@techreport{oai:jaxa.repo.nii.ac.jp:00043579, author = {佐藤, 浩 and 斉藤, 博之助 and 中村, 宏 and Sato, H. and Saito, H. and Nakamura, H.}, month = {Jun}, note = {The separation of laminar boundary layer was observed in the flow of water by hydrogen bubble technique and hot-wire velocimeter. The purpose of experiment is to compare results of two different methods. The separation was caused by 4 different devices including a fence, a semi-cylinder in the boundary layer and sepsration from trailing edge. In all cases we observed the remarkable disagreement between two results. It is clear that in order to understand complicated turbulent flows we have to use all available devices and fuse them by numerical computations., 資料番号: NALSP0059007, レポート番号: NAL SP-59}, title = {層流境界層の剥離の実験}, year = {2003} }