{"created":"2023-06-20T15:14:05.886353+00:00","id":44072,"links":{},"metadata":{"_buckets":{"deposit":"ddc74bc4-46bd-4e63-ba7e-7e03abbfc581"},"_deposit":{"created_by":1,"id":"44072","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"44072"},"status":"published"},"_oai":{"id":"oai:jaxa.repo.nii.ac.jp:00044072","sets":["1887:1893","1896:1898:1913:1916"]},"author_link":["467477","467478","467473","467480","467475","467482","467476","467481","467479","467474"],"item_3_biblio_info_10":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1983-03","bibliographicIssueDateType":"Issued"},"bibliographicPageStart":"29","bibliographicVolumeNumber":"489","bibliographic_titles":[{"bibliographic_title":"航空宇宙技術研究所資料"},{"bibliographic_title":"Technical Memorandum of National Aerospace Laboratory","bibliographic_titleLang":"en"}]}]},"item_3_description_16":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"通商産業省工業技術院の大型工業技術研究開発制度による「航空機用ジェットエンジンの研究開発」の一環として,当研究所が行ってきた高圧タービン冷却翼性能向上の研究において,主要な試験設備である「タービン翼冷却試験用高温高圧翼列風胴」の全体計画と設計製作の概要を第1報に報告した。本報ではこの試験設備の各構成要素について,各種特性試験の結果及び運転・試験を経過して行った改修,発生した問題点とその対策等を報告する。","subitem_description_type":"Abstract"}]},"item_3_description_32":{"attribute_name":"資料番号","attribute_value_mlt":[{"subitem_description":"資料番号: NALTM0489000","subitem_description_type":"Other"}]},"item_3_description_33":{"attribute_name":"レポート番号","attribute_value_mlt":[{"subitem_description":"レポート番号: NAL TM-489","subitem_description_type":"Other"}]},"item_3_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"航空宇宙技術研究所"}]},"item_3_publisher_9":{"attribute_name":"出版者(英)","attribute_value_mlt":[{"subitem_publisher":"National Aerospace Laboratory(NAL)"}]},"item_3_source_id_21":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0452-2982","subitem_source_identifier_type":"ISSN"}]},"item_3_source_id_24":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00314334","subitem_source_identifier_type":"NCID"}]},"item_3_text_6":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"航空宇宙技術研究所原動機部"},{"subitem_text_value":"航空宇宙技術研究所原動機部"},{"subitem_text_value":"航空宇宙技術研究所原動機部"},{"subitem_text_value":"航空宇宙技術研究所原動機部"},{"subitem_text_value":"航空宇宙技術研究所航空機公害グループ"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"吉田, 豊明"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"熊谷, 隆王"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"坂田, 公夫"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"臼井, 弘"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"進藤, 重美"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"YOSHIDA, Toyoaki","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"KUMAGAI, Takao","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"SAKATA, Kimio","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"USUI, Hiroshi","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"SHINDO, Shigemi","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-01-28"}],"displaytype":"detail","filename":"naltm00489.pdf","filesize":[{"value":"2.8 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"naltm00489.pdf","url":"https://jaxa.repo.nii.ac.jp/record/44072/files/naltm00489.pdf"},"version_id":"f7b205c5-3d15-4ac2-8cd0-04889476e2dd"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"technical report","resourceuri":"http://purl.org/coar/resource_type/c_18gh"}]},"item_title":"タービン翼冷却試験用高温高圧翼列風胴(Ⅱ)特性試験結果","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"タービン翼冷却試験用高温高圧翼列風胴(Ⅱ)特性試験結果"}]},"item_type_id":"3","owner":"1","path":["1893","1916"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-03-26"},"publish_date":"2015-03-26","publish_status":"0","recid":"44072","relation_version_is_last":true,"title":["タービン翼冷却試験用高温高圧翼列風胴(Ⅱ)特性試験結果"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-06-20T22:03:08.499434+00:00"}