{"created":"2023-06-20T15:15:03.542173+00:00","id":45105,"links":{},"metadata":{"_buckets":{"deposit":"3aefee30-c151-4327-b7de-9e1c7c90cf8e"},"_deposit":{"created_by":1,"id":"45105","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"45105"},"status":"published"},"_oai":{"id":"oai:jaxa.repo.nii.ac.jp:00045105","sets":["1887:1893","1896:1898:1913:1917"]},"author_link":["472948","472951","472952","472954","472946","472950","472953","472955","472947","472949","472945","472944"],"item_3_alternative_title_2":{"attribute_name":"その他のタイトル(英)","attribute_value_mlt":[{"subitem_alternative_title":"On Power Efficient Operation of the 2m × 2m Transonic Wind Tunnel at the National Aerospace Laboratory"}]},"item_3_biblio_info_10":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1984-12","bibliographicIssueDateType":"Issued"},"bibliographicPageStart":"22","bibliographicVolumeNumber":"847","bibliographic_titles":[{"bibliographic_title":"航空宇宙技術研究所報告"},{"bibliographic_title":"Technical Report of National Aerospace Laboratory TR-847","bibliographic_titleLang":"en"}]}]},"item_3_description_17":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"In the conventional test procedure using the 2m × 2m transonic wind tunnel of the National Aerospace Laboratory, an auxiliary power unit is operated synergistically for Mach numbers near and above unity in order to establish the desired Mach number at the test section by suction through the perforated test section walls. This power unit consumes a considerable amount of electricity (a maximum of 12000kW). Therefore, as part of the research to explore the possibility of saving energy in wind tunnel operation, an investigation is made here as to what extent the test Mach number can be increased without the use of the auxiliary power unit. It is found that a Mach number of 1.06 is attained by adequately adjusting several geometric parameters such as diverging angle of the side walls of the test section, opening width of the diffuser flaps, width of the second throat and the flexible nozzle setting. Electric power of 7800kW can be saved at Mach number 1 by using this procedure compared with the conventional procedure in which an auxiliary fan is used. Mach number distributions at the test section are found to be little influenced by these adjustments.","subitem_description_type":"Other"}]},"item_3_description_32":{"attribute_name":"資料番号","attribute_value_mlt":[{"subitem_description":"資料番号: NALTR0847000","subitem_description_type":"Other"}]},"item_3_description_33":{"attribute_name":"レポート番号","attribute_value_mlt":[{"subitem_description":"レポート番号: NAL TR-847","subitem_description_type":"Other"}]},"item_3_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"航空宇宙技術研究所"}]},"item_3_publisher_9":{"attribute_name":"出版者(英)","attribute_value_mlt":[{"subitem_publisher":"National Aerospace Laboratory(NAL)"}]},"item_3_source_id_21":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0389-4010","subitem_source_identifier_type":"ISSN"}]},"item_3_text_6":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"航空宇宙技術研究所空気力学第二部"},{"subitem_text_value":"航空宇宙技術研究所空気力学第二部"},{"subitem_text_value":"航空宇宙技術研究所空気力学第二部"},{"subitem_text_value":"航空宇宙技術研究所空気力学第二部"},{"subitem_text_value":"航空宇宙技術研究所空気力学第二部"},{"subitem_text_value":"航空宇宙技術研究所空気力学第二部"}]},"item_3_text_7":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Second Aerodynamics Division, National Aerospace Laboratory(NAL)"},{"subitem_text_language":"en","subitem_text_value":"Second Aerodynamics Division, National Aerospace Laboratory(NAL)"},{"subitem_text_language":"en","subitem_text_value":"Second Aerodynamics Division, National Aerospace Laboratory(NAL)"},{"subitem_text_language":"en","subitem_text_value":"Second Aerodynamics Division, National Aerospace Laboratory(NAL)"},{"subitem_text_language":"en","subitem_text_value":"Second Aerodynamics Division, National Aerospace Laboratory(NAL)"},{"subitem_text_language":"en","subitem_text_value":"Second Aerodynamics Division, National Aerospace Laboratory(NAL)"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"白井, 正孝"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"中村, 正剛"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"鈴木, 正光"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"小池, 陽"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"鈴木, 弘一"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"神谷, 信彦"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"SHIRAI, Masataka","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"NAKAMURA, Seigou","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"SUZUKI, Masamitsu","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"KOIKE, Akira","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"SUZUKI, Koichi","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"KAMIYA, Nobuhiko","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-01-29"}],"displaytype":"detail","filename":"naltr00847.pdf","filesize":[{"value":"1.4 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"naltr00847.pdf","url":"https://jaxa.repo.nii.ac.jp/record/45105/files/naltr00847.pdf"},"version_id":"f5d4761a-0334-4a0a-83b1-92713ecef83c"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"technical report","resourceuri":"http://purl.org/coar/resource_type/c_18gh"}]},"item_title":"航空宇宙技術研究所2m×2m遷音速風洞の省電力運転法の研究","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"航空宇宙技術研究所2m×2m遷音速風洞の省電力運転法の研究"}]},"item_type_id":"3","owner":"1","path":["1893","1917"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-03-26"},"publish_date":"2015-03-26","publish_status":"0","recid":"45105","relation_version_is_last":true,"title":["航空宇宙技術研究所2m×2m遷音速風洞の省電力運転法の研究"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-06-20T21:45:12.703090+00:00"}