| Item type |
テクニカルレポート / Technical Report(1) |
| 公開日 |
2015-03-26 |
| タイトル |
|
|
タイトル |
電子式高速多点圧力変換器(ESP)を用いた吹出式遷音速風洞の圧力計測 |
| 言語 |
|
|
言語 |
jpn |
| 資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_18gh |
|
資源タイプ |
technical report |
| その他のタイトル(英) |
|
|
その他のタイトル |
A Pressure Measuring System Using Electronically Scanned Pressure Sensors (ESP) Installed in a Transonic Blowdown Wind Tunnel |
| 著者 |
藤田, 敏美
室田, 勝一
鈴木, 弘一
FUJITA, Toshimi
MUROTA, Katsuichi
SUZUKI, Koichi
|
| 著者所属 |
|
|
|
航空宇宙技術研究所新型航空機研究グループ |
| 著者所属 |
|
|
|
航空宇宙技術研究所空気力学第二部 |
| 著者所属 |
|
|
|
航空宇宙技術研究所空気力学第二部 |
| 著者所属(英) |
|
|
|
en |
|
|
V/STOL Aircraft Research Group, National Aerospace Laboratory(NAL) |
| 著者所属(英) |
|
|
|
en |
|
|
Second Aerodynamics Division, National Aerospace Laboratory(NAL) |
| 著者所属(英) |
|
|
|
en |
|
|
Second Aerodynamics Division, National Aerospace Laboratory(NAL) |
| 出版者 |
|
|
出版者 |
航空宇宙技術研究所 |
| 出版者(英) |
|
|
出版者 |
National Aerospace Laboratory(NAL) |
| 書誌情報 |
航空宇宙技術研究所報告
en : Technical Report of National Aerospace Laboratory TR-883
巻 883,
p. 49,
発行日 1985-10
|
| 抄録(英) |
|
|
内容記述タイプ |
Other |
|
内容記述 |
A pressure measuring system using electrically scanned pressure sensors (ESP) was built and installed in a transonic blowdown wind tunnel, and thoroughly tested to see how effective an ESP system is in enhancing data productivity when compared with the scanivalve system hitherto used. After a brief description of what an ESP is and how to use it, detailed results are given of studies in which linearity, stability and repeatability characteristics of our ESP system was examined. It is shown that the deviation of the system output from linearity is less than 0.25% of the full-scale value (FS), that the thermal zero shift is of negligible magnitude (less than a quarter of 0.1% of FS) and that the repeatability is also quite satisfactory. The pressure sensors were placed in the plenum chamber surrounding the test section, where the temperature change during the tunnel operation remains rather small (generally about 1C). This environmental stability contributed to the excellent performance of our pressure measuring system. The time needed for the measurements of pressures on and about an airfoil model (42 static pressures on the surface and 35 total pressures in the wake) is 8 seconds whereas it has been 43 seconds with the Former scanivalve system. The data transfer time continues to be disproportionate - 35 seconds - as long as the data processing unit is unchanged. Thus, concurrent improvement in the data processing unit is necessary if the maximum benefit is to be obtained from the installation of an ESP system. |
| ISSN |
|
|
収録物識別子タイプ |
ISSN |
|
収録物識別子 |
0389-4010 |
| 資料番号 |
|
|
内容記述タイプ |
Other |
|
内容記述 |
資料番号: NALTR0883000 |
| レポート番号 |
|
|
内容記述タイプ |
Other |
|
内容記述 |
レポート番号: NAL TR-883 |