{"created":"2023-06-20T14:38:05.958948+00:00","id":4572,"links":{},"metadata":{"_buckets":{"deposit":"910e9671-d2e0-4c56-bfea-ac374352420a"},"_deposit":{"created_by":1,"id":"4572","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"4572"},"status":"published"},"_oai":{"id":"oai:jaxa.repo.nii.ac.jp:00004572","sets":["1887:1893","9:789:906:914"]},"author_link":["20628","20629","20627"],"item_3_biblio_info_10":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2011","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"PI228-4","bibliographicPageStart":"PI228-1","bibliographicVolumeNumber":"JAXA-SP-11-007E","bibliographic_titles":[{"bibliographic_title":"宇宙航空研究開発機構特別資料"},{"bibliographic_title":"JAXA Special Publication: Final Reports of the ALOS Research Announcement Programs 1&2, 2011","bibliographic_titleLang":"en"}]}]},"item_3_description_17":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"Polarimetric PALSAR system parameters are assessed using data sets collected over various calibration sites. The data collected over the Amazonian forest permits validating the zero Faraday rotation hypotheses near the equator. The analysis of the Amazonian forest data and the response of the corner reflectors deployed during the PALSAR acquisitions lead to the conclusion that the antenna is highly isolated (better than -35 dB). Theses results are confirmed using data collected over the Sweden and Ottawa calibration sites. The 5-m height trihedrals deployed in the Sweden calibration site by the Chalmers University of technology permits accurate measurement of antenna parameters, and detection of 2-3 degree Faraday rotation during day acquisition, whereas no Faraday rotation was noted during night acquisition. Small Faraday rotation angles (2-3 degree) have been measured using acquisitions over the DLR Oberpfaffenhofen and the Ottawa calibration sites. The presence of small but still significant Faraday rotation (2-3 degree) induces a CR return at the cross-polarization HV and VH that should not be interpreted as the actual antenna cross-talk. PALSAR antenna is highly isolated (better than -35 dB), and diagonal antenna distortion matrices (with zero cross-talk terms) can be used for accurate calibration of PALSAR polarimetric data.","subitem_description_type":"Other"}]},"item_3_description_18":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"形態: カラー図版あり","subitem_description_type":"Other"},{"subitem_description":"形態: DVD-ROM1枚","subitem_description_type":"Other"}]},"item_3_description_19":{"attribute_name":"内容記述(英)","attribute_value_mlt":[{"subitem_description":"Physical characteristics: Original contains color illustrations","subitem_description_type":"Other"},{"subitem_description":"Note: One DVD-ROM","subitem_description_type":"Other"}]},"item_3_description_32":{"attribute_name":"資料番号","attribute_value_mlt":[{"subitem_description":"資料番号: AA0065135102","subitem_description_type":"Other"}]},"item_3_description_33":{"attribute_name":"レポート番号","attribute_value_mlt":[{"subitem_description":"レポート番号: JAXA-SP-11-007E","subitem_description_type":"Other"}]},"item_3_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"宇宙航空研究開発機構地球観測研究センター (JAXA)(EORC)"}]},"item_3_publisher_9":{"attribute_name":"出版者(英)","attribute_value_mlt":[{"subitem_publisher":"Earth Observation Research Center, Japan Aerospace Exploration Agency (JAXA)(EORC)"}]},"item_3_source_id_21":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1349-113X","subitem_source_identifier_type":"ISSN"}]},"item_3_source_id_24":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA11984031","subitem_source_identifier_type":"NCID"}]},"item_3_text_6":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_text_value":"宇宙航空研究開発機構 (JAXA)"}]},"item_3_text_7":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Canada Centre for Remote Sensing, Natural Resources Canada"},{"subitem_text_language":"en","subitem_text_value":"Japan Aerospace Exploration Agency (JAXA)"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"島田, 政信"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Touzi, Ridha","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Shimada, Masanobu","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-01-16"}],"displaytype":"detail","filename":"65135102.pdf","filesize":[{"value":"227.0 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"65135102.pdf","url":"https://jaxa.repo.nii.ac.jp/record/4572/files/65135102.pdf"},"version_id":"426bc5a6-dfdd-483a-8b8d-0ba2f37ca47d"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Radar Polarimetry","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Synthetic aperture","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"radar","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Calibration","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Faraday rotation","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"technical report","resourceuri":"http://purl.org/coar/resource_type/c_18gh"}]},"item_title":"Polarimetric PALSAR System Model Assessment and Calibration","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Polarimetric PALSAR System Model Assessment and Calibration","subitem_title_language":"en"}]},"item_type_id":"3","owner":"1","path":["914","1893"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-03-26"},"publish_date":"2015-03-26","publish_status":"0","recid":"4572","relation_version_is_last":true,"title":["Polarimetric PALSAR System Model Assessment and Calibration"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-06-21T08:36:22.514688+00:00"}