@inproceedings{oai:jaxa.repo.nii.ac.jp:00005680, author = {青木, 良尚 and 細江, 信幸 and 星野, 秀雄 and 伊藤, 健 and Aoki, Yoshihisa and Hosoe, Nobuyuki and Hoshino, Hideo and Ito, Takeshi}, book = {宇宙航空研究開発機構特別資料: 第78回風洞研究会議論文集, JAXA Special Publication: Proceedings of the Wind Tunnel Technology Association 78th Meeting}, month = {Aug}, note = {The Sensorex and Q-Flex type inclinometer calibration facility in JAXA Wintec was developed in August, 2003. The Inclinometer Calibration Facility is introduced and 2-axis servo inclinometer calibration formula based on servo inclinometer model is derived in this paper. With an example for a wind tunnel testing using the Sensorex41400 servo inclinometer conducted in JAXA 6.5- by 5.5- m Low Speed Wind Tunnel, we show the application of the inclinometer to the wind tunnel testing., 資料番号: AA0063607003, レポート番号: JAXA-SP-07-005}, pages = {26--32}, publisher = {宇宙航空研究開発機構, Japan Aerospace Exploration Agency (JAXA)}, title = {JAXA風洞技術開発センター傾斜計校正装置と内装式傾斜計の応用}, volume = {JAXA-SP-07-005}, year = {2007} }