@techreport{oai:jaxa.repo.nii.ac.jp:00006259, author = {川崎, 春夫 and 矢部, 高宏 and 岡本, 篤 and 野田, 浩幸 and Kawasaki, Haruo and Yabe, Takahiro and Okamoto, Atsushi and Noda, Hiroyuki}, month = {Jan}, note = {The Deployable Radiator (DPR) with looped heat pipe is planed in Engineering Test Satellite. The loop heat pipes are able to transport heat over long distances in satellite. The thermal control systems such as the loop heat pipes are demanded with precise control and expected to operate on orbit for 10 to 20 years. The non-condensable gas in loop heat pipe with working fluid affects the precise control and performance. The paper describes an investigation into operating characteristics of loop heat pipe in DPR and an effect of non condensable gas., 資料番号: AA0049054003, レポート番号: JAXA-SP-05-008}, title = {技術試験衛星8型展開ラジエータ(DPR)の地上特性評価試験結果報告}, year = {2006} }