Item type |
会議発表論文 / Conference Paper(1) |
公開日 |
2015-03-26 |
タイトル |
|
|
タイトル |
EFD/CFD融合技術に基づくアブレーション熱防御システム評価手法の研究 |
言語 |
|
|
言語 |
jpn |
資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_5794 |
|
資源タイプ |
conference paper |
その他のタイトル(英) |
|
|
その他のタイトル |
Study of Evaluation of Ablation Thermal Protection System Based on Integration of EFD and CFD |
著者 |
鈴木, 俊之
藤田, 和央
酒井, 武治
奥山, 圭一
加藤, 純郎
西尾, 誠司
Suzuki, Toshiyuki
Fujita, Kazuhisa
Sakai, Takeharu
Okuyama, Keiichi
Kato, Sumio
Nishio, Seiji
|
著者所属 |
|
|
|
宇宙航空研究開発機構 |
著者所属 |
|
|
|
宇宙航空研究開発機構 |
著者所属 |
|
|
|
名古屋大学 |
著者所属 |
|
|
|
愛知工科大学 |
著者所属 |
|
|
|
琉球大学 |
著者所属 |
|
|
|
川崎重工業 |
著者所属(英) |
|
|
|
en |
|
|
Japan Aerospace Exploration Agency (JAXA) |
著者所属(英) |
|
|
|
en |
|
|
Japan Aerospace Exploration Agency (JAXA) |
著者所属(英) |
|
|
|
en |
|
|
Nagoya University |
著者所属(英) |
|
|
|
en |
|
|
Aichi University of Technology |
著者所属(英) |
|
|
|
en |
|
|
University of Ryukyus |
著者所属(英) |
|
|
|
en |
|
|
Kawasaki Heavy Industries |
出版者 |
|
|
出版者 |
宇宙航空研究開発機構 |
出版者(英) |
|
|
出版者 |
Japan Aerospace Exploration Agency (JAXA) |
書誌情報 |
宇宙航空研究開発機構特別資料: 第42回流体力学講演会/航空宇宙数値シミュレーション技術シンポジウム2010 論文集
en : JAXA Special Publication: Proceedings of 42nd Fluid Dynamics Conference / Aerospace Numerical Simulation Symposium 2010
巻 JAXA-SP-10-012,
発行日 2011-02-28
|
会議概要(会議名, 開催地, 会期, 主催者等) |
|
|
内容記述タイプ |
Other |
|
内容記述 |
第42回流体力学講演会/航空宇宙数値シミュレーション技術シンポジウム2010 (2010年6月24日-25日. 米子コンベンションセンター BiG SHiP) |
会議概要(会議名, 開催地, 会期, 主催者等)(英) |
|
|
内容記述タイプ |
Other |
|
内容記述 |
42nd Fluid Dynamics Conference / Aerospace Numerical Simulation Symposium 2010 (June 24-25, 2010. Yonago Convention Center BiG SHiP), Yonago, Tottori Japan |
抄録(英) |
|
|
内容記述タイプ |
Other |
|
内容記述 |
Cloth-layered carbon fiber reinforced plastic ablator with a specific gravity of about 1.5 is developed to examine the prediction accuracy of analysis methods associated with the thermal response of ablator. Heating tests are carried out in the arcjet wind tunnel to quantify the thermal performance of ablator so developed. In the tests, the surface temperatures and in-depth temperatures of ablative test pieces are measured during the testing. The experimental results obtained in the heating tests are analyzed by using a two-dimensional analysis method developed earlier. In the method, the thermal response of ablator is calculated by loosely coupling the shock layer computational fluid dynamics code and the 2-D version of ablation code using an arcjet freestream condition. The arcjet freestream condition in the test section is evaluated by calculating the flows in the arcjet wind tunnel fully theoretically. The present analyses are made especially focusing on an anisotropic nature of thermal conduction of ablator. Thermal conduction inside the ablator is modeled in the code based on measured thermal conductivity values for different ply angles. By comparing the calculated results with the arcjet data, the prediction accuracy of thermal response models of ablator is discussed. |
内容記述 |
|
|
内容記述タイプ |
Other |
|
内容記述 |
形態: カラー図版あり |
内容記述(英) |
|
|
内容記述タイプ |
Other |
|
内容記述 |
Physical characteristics: Original contains color illustrations |
ISSN |
|
|
収録物識別子タイプ |
ISSN |
|
収録物識別子 |
1349-113X |
書誌レコードID |
|
|
収録物識別子タイプ |
NCID |
|
収録物識別子 |
AA11984031 |
資料番号 |
|
|
内容記述タイプ |
Other |
|
内容記述 |
資料番号: AA0064967036 |
レポート番号 |
|
|
内容記述タイプ |
Other |
|
内容記述 |
レポート番号: JAXA-SP-10-012 |